WARNING! Do not exceed 24Vdc or 10mA into any optoisolator input. Use
care to observe the correct signal polarities or damage may occur! Do not
exceed 250 Vac or 1 Amp through any relay output.
I/O Pinout
Three inputs and three outputs are provided per connector
Connector I/O 1-3
Connector I/O 4-6
Pin# Signal
Pin# Signal
1
OUT1 Common
1
OUT4 Common
2
OUT1 Normally Closed
2
OUT4 Normally Closed
3
OUT1 Normally Open
3
OUT4 Normally Open
4
OUT2 Common
4
OUT5 Common
5
OUT2 Normally Closed
5
OUT5 Normally Closed
6
OUT2 Normally Open
6
OUT5 Normally Open
7
OUT3 Common
7
OUT6 Common
8
OUT3 Normally Closed
8
OUT6 Normally Closed
9
OUT3 Normally Open
9
OUT6 Normally Open
10 IN1
10
IN4
11
IN1 Common
11
IN4 Common
12 IN2
12
IN5
13
IN2 Common
13
IN5 Common
14
IN3
14
IN6
15
IN3 Common
15
IN6 Common
16
Cable Shield
16
Cable Shield
Connector I/O 7-9
Connector I/O 10-12
Pin# Signal
Pin# Signal
1
OUT7 Common
1
OUT10 Common
2
OUT7 Normally Closed
2
OUT10 Normally Closed
3
OUT7 Normally Open
3
OUT10 Normally Open
4
OUT8 Common
4
OUT11 Common
5
OUT8 Normally Closed
5
OUT11 Normally Closed
6
OUT8 Normally Open
6
OUT11 Normally Open
7
OUT9 Common
7
OUT12 Common
8
OUT9 Normally Closed
8
OUT12 Normally Closed
9
OUT9 Normally Open
9
OUT12 Normally Open
10 IN7
10
IN10
11
IN7 Common
11
IN10 Common
12
IN8
12
IN11 (shared w/ lifter Lower
limit input)
13
IN8 Common
13
IN11 Common
14
IN9
14
IN12 (shared w/ lifter Upper
limit input)
15
IN9 Common
15
IN12 Common
16
Cable Shield
16