8
The E.A.H.S. system comes with Gullco’s standard 4” linear slide and Gullco’s 1-1/8”
diameter clamp adapter block assembly. This assembly can be mounted to standard Gullco
1-1/8” or 1-1/2” rack arm.
The Gullco standard torch gun holder also comes standard. The 6’-6” long slide control
cable must be connected to the remote pendant and to the slide before the E.A.H.S. is
powered up, and can only be removed when the power is OFF. Not doing so could result in
control damage.
Note: If other torch mounting hardware is used that was not supplied by Gullco to mount
the torch to the slide, it is important that the torch is electrical isolated from the slide. i.e. no
welding current from the torch must be allowed to pass through the slide. Failure to do so
will result in damage to the E.A.H.S. controls. It is recommended that you consult your
local Gullco representative when considering other torch mounting hardware.