FIRMWARE VERSION 1.0.14.1 HT502 USER MANUAL Page 38 of 54
Syslog Level
Select the HT502 to report the log level. Default is NONE. The level is one of DEBUG,
INFO, WARNING or ERROR. Syslog messages are sent based on the following events:
1. product model/version on boot up (INFO level)
2. NAT related info (INFO level)
3. sent or received SIP message (DEBUG level)
4. SIP message summary (INFO level)
5. inbound and outbound calls (INFO level)
6. registration status change (INFO level)
7. negotiated codec (INFO level)
8. Ethernet link up (INFO level)
9. SLIC chip exception (WARNING and ERROR levels)
10.
memory exception (ERROR level)
The Syslog uses USER facility. In addition to standard Syslog payload, it contains the
following components:
GS_LOG: [device MAC address][error code] error message
Example: May 19 02:40:38 192.168.1.14 GS_LOG: [00:0b:82:00:a1:be][000] Ethernet link
is up
Send SIP Log
If Syslog is enabled and Send SIP Log is set to YES, then SIP messages will also be
delivered via Syslog. Default is set to NO.
Download Device
Configuration
Allows user to download and save a text file containing all the P values of each setting as
configured at that point on the unit. (Note: For Security Reasons, all Passwords
won’t be
Downloaded)
Download Device XML
Configuration
Allows user to download and save a XML file containing all the P values of each setting as
configured at that point on the unit. (Note: For Security Reasons, all Passwords won’t be
Downloaded)
Upload firmware
Allows user to upload firmware file from local directory.
Upload configuration
Allows user to upload configuration file from local directory.
TABLE 10: ACCOUNT SETTINGS
Profile Active
When set to Yes the FXS port is activated.
Primary SIP Server
SIP Server’s IP address or Domain name provided by VoIP service provider.