Specifications – GBS Elektronik MCA 166 User Manual
Page 12

_______________________________________________________________________
12
Specifications:
All outputs are short circuit proof. Overloading of any output leads to shutdown of all
output supply voltages (except the MCA Batt output)
Ripple on all regulated outputs: <20mVpp on +5V, <6 mVpp on all other outputs. Ripple
measured with outputs loaded to 100 mA.
Operating temperature -5 ...+50°C
Size 155*95*50 mm, same as MCA166
Water and Dust protection IP42
6W total power output maximum
Contains 3 camcorder type Li-Ion batteries, 4 Ah/ 30Wh
Standby current (power supply switched on, no load): 35mA
Overload recognition: If all output voltages are correctly present, the indicator LED is
blinking with a frequency of about 0.5 Hz. If there is a voltage drop of more than 10%,
then the LED starts blinking fast (3 Hz); and if this persists for more than 1.5 seconds, the
power supply is switched off. To reset the power supply, switch it off, wait a second and
then switch it on again.
Charge input connector
Contact
Signal
1
+ charge voltage (8.4V,1A max)
2
- charge voltage
MCA Batt output connector
6.6..8.2V, depending on Battery charge state, 1A max.
Wiring of Output connector same as input connector
Power Supply Connectors (D9 female) + BNC
Contact
Voltage
warranted
Current
for
output voltage
within +/- 5%
max. Current
before
switching of.
D9-1
GND
D9-2
GND
D9-3
+5 +/-0.25V
300 mA
550 mA
D9-4
+12 +/- 0.6 V
130 mA
570 mA
D9-5
-
D9-6
-24 +/- 1.2 V
100mA
150 mA
D9-7
+24 +/- 1.2 V
100 mA
160 mA
D9-8
-
D9-9
-12 +/- 0.6 V
130 mA
260 mA
BNC
Connected to
D9-3
all current under condition that the total power output limit is not exceeded.