beautypg.com

Operation, Danger, Warning – Desa Mgh3000 User Manual

Page 18: General information, Using receptacle

background image

18

120 VOLTS

120/240 VOLTS

FULL POWER

SELECTOR

120

ONLY

120

240V

RESET

RESET

TEST

RESET

RESET

OPERATION

Figure 13 - Receptacle Locations

120V, 30-Amp
Twist-Lock

120V, 15-Amp GFCI Duplex

Model MGH3000 has only the 120V, 15-amp GFCI duplex receptacle.

120/240V, 20 or
30-Amp Twist-Lock

GENERAL INFORMATION

This generator is not large enough to power your entire home. Do not connect
generator to any existing electrical circuits. Plug items directly into generator
receptacles. Do not exceed amperage rating of receptacles. Only use grounded
cords.

DANGER

Use only in well-vented areas. Make sure area has
plenty of free-moving, fresh, outside air. Never run
generator in an enclosed or confined area. Never run
generator inside occupied building. Engine exhaust
contains poisonous carbon monoxide gas.
Overexposure will cause loss of consciousness
and will lead to death.

WARNING

Never connect generator to any existing electrical
circuits. The generator output will back-feed into the
utility power line. This may electrocute a power
company line repair person. Also, if generator is
powering electrical circuits, the chance of an
electrical fire exists.

Note:

We supply the engine owner’s manual with generator. Refer to that manual

for questions concerning engine operation.

USING RECEPTACLE

Note:

Do not exceed amperage rating of receptacles. Exceeding rating will trip

receptacle circuit breaker.

Use receptacles properly. Improper use could damage generator. Use only
grounded extension cords. Power only grounded or double-insulated items. Do not
overload receptacles. All generators (except model MGH3000) have the following
receptacles (see Figure 13):

• 120V, 15-amp GFCI duplex receptacle
• 120V, 30-amp twist-lock receptacle
• 120/240V, 20 or 30-amp twist-lock receptacle