PMAC2A PC104 Hardware Reference Manual
Base Board E-Point Jumper Descriptions
44
E18 – E19: PC/104 Bus Address
E Point and Physical
Layout
Location Description
Default
Jumpers E18 and E19 select the PC/104 bus
address for communications according to
the following table:
No E18 jumper installed;
Jumper E19 installed
E18 E19
Address
(Hex)
Address
(Dec)
OFF OFF $200
512
OFF ON $210
528
ON OFF $220
544
E18
E19
D4
ON ON $230
560
Note:
Jumper E18 must be removed and jumper E19 must be installed for using either