beautypg.com

E18 – e19: pc/104 bus address – Delta Tau PMAC2A-PC/104 User Manual

Page 50

background image

PMAC2A PC104 Hardware Reference Manual

Base Board E-Point Jumper Descriptions

44

E18 – E19: PC/104 Bus Address

E Point and Physical

Layout

Location Description

Default

Jumpers E18 and E19 select the PC/104 bus
address for communications according to
the following table:

No E18 jumper installed;

Jumper E19 installed

E18 E19

Address

(Hex)

Address

(Dec)

OFF OFF $200

512

OFF ON $210

528

ON OFF $220

544

E18

E19

D4

ON ON $230

560

Note:

Jumper E18 must be removed and jumper E19 must be installed for using either
the Ethernet or USB optional methods of communication.