Flowserve 3400MD Digital Positioner User Manual
Page 31
![background image](https://www.manualsdir.com/files/784836/content/doc031.png)
31
Logix 3400MD Digital Positioner FCD LGENIM3404-08-AQ – 5/15
flowserve.com
Fieldbus
Block Index
Fieldbus
Variable Name
Transducer
Block
Fieldbus
Datatypes
Logix Positioner
Description
Register
Type
Fix
Pt
Rd
Variable
Name
R/W
19
POSITIONER_
MASK
XDTB_
MAIN
BIT_STRING
271
U_CHAR
NO
Positioner_
Mask
NRW
Status, Alarm, Positioner
Flags
15
MECHANICAL_
MASK
XDTB_MD
BIT_STRING
272
U_CHAR
NO
Mechanical_
Mask
NRW
Status, Alarm, Mechanical
Flags
14
ELECTRONIC_
MASK
XDTB_
TECH
BIT_STRING
274
U_CHAR
NO
Electronic_
Mask
NRW
Status, Alarm, Electronic
Flags
22
PRESSURE_
MASK
XDTB_
TECH
BIT_STRING
275
U_CHAR
NO
Pres-
sure_Mask
NRW
Status, Alarm, Pressure
Flags
16
INNERLOOP_
MASK
XDTB_
TECH
BIT_STRING
276
U_CHAR
NO
Inner
Loop_Mask
NRW
Status, Alarm, Inner Loop
Flags
18
OUTERLOOP_
MASK
XDTB_
TECH
BIT_STRING
277
U_CHAR
NO
Outer
Loop_Mask
NRW
Status, Alarm, Outer Loop
Flags
20
CONFIGURA-
TION_MASK
XDTB_
TECH
BIT_STRING
279
U_CHAR
NO
Configura-
tion_ Mask
NRW
Status, Alarm, Configuration
Flags
113
BLINK_CODE
XDTB_
MAIN
UNSIGNED 8
283
U_CHAR
NO
Blink_Code
R
LED Status Blink Code
Pro Mode Parameters
24
PST_TIME_
BREAKAWAY
XDTB_MD
FLOAT
285
U_INT
/100
PST_Time-
Breakaway
NR
Partial Stroke Test breakaway
time
25
PST_PRES-
SURE_DIFF
XDTB_MD
FLOAT
286
U_INT
/100
PST_Pres-
sureDiff
R
Partial Stroke Test Pressure
Differential
26
PST_TIME_TO_
TARGET
XDTB_MD
FLOAT
287
U_INT
/100
PST_TimeTo-
Target
NR
Partial Stroke Test Time to
Target
27
PST_RESULT
XDTB_MD
UNSIGNED 8
288
U_CHAR
NO
PST_Result
R
Partial Stroke Test Result
(Pass or Fail)
28
PST_TIME_
LIMIT
XDTB_MD
FLOAT
289
U_INT
/100
PST_Time-
Limit
RW
Partial Stroke Test Time Limit
29
ACTUATOR_
RATIO
XDTB_MD
FLOAT
290
U_INT
/100
Actua-
tion_Ratio
RW
Actuation Ratio In Percent
30
ACTUATION_
RATIO_HIGH_
START_LIMIT
XDTB_MD
FLOAT
291
U_INT
/100
AR_HighStar-
tLimit
RW
Actuation Ratio High Start
Limit
31
ACTUATION_
RATIO_HIGH_
END_LIMIT
XDTB_MD
FLOAT
292
U_INT
/100
AR_HighEnd
Limit
RW
Actuation Ratio High End
Limit
32
ACTUA-
TION_RATIO_
PERCENT_
YELLOW
XDTB_MD
FLOAT
293
U_INT
/100
AR_Percent
Yellow
NR
Actuation Ration Percent
Yellow
50
SPOOL_
RESPONSE_
TIME
XDTB_MD
FLOAT
295
U_INT
NO
Spool_
Time_86
NR
Spool Response Time
51
SPOOL_START_
LIMIT
XDTB_MD
FLOAT
296
U_INT
NO
SS_LowLimit
NRW
Spool Start Limit
52
SPOOL_END_
LIMIT
XDTB_MD
FLOAT
297
U_INT
NO
SS_highLimit
NRW
Spool End Limit
53
SPOOL_
PERCENT
XDTB_MD
FLOAT
298
U_INT
/100
SS_pctYellow R
Spool Percent Yellow
16
VALVE_TRAVEL_
DISTANCE
XDTB_MD
FLOAT
301
U_LONG
/100
ValveTravel
Distance
R
Valve Travel Distance
17
VALVE_TRAVEL_
HIGH_START
XDTB_MD
FLOAT
302
U_LONG
/100
ValveTravel-
High Start
RW
Valve Travel High Start
18
VALVE_TRAVEL_
HIGH_END
XDTB_MD
FLOAT
303
U_LONG
/100
ValveTravel-
High End
RW
Valve Travel High End