Flowserve 3400MD Digital Positioner User Manual
Page 28
![background image](https://www.manualsdir.com/files/784836/content/doc028.png)
Logix 3400MD Digital Positioner FCD LGENIM3404-08-AQ –5/15
28
Fieldbus
Block Index
Fieldbus
Variable Name
Transducer
Block
Fieldbus
Datatypes
Logix Positioner
Description
Register
Type
Fix
Pt
Rd
Variable
Name
R/W
61
SIG_FLAGS
XDTB_
MAIN
BIT_STRING
146
U_CHAR
NO
SIGflags
NRW
Signature status and
command flags
60
SIG_INDEX
XDTB_
MAIN
UNSIGNED 16
147
U_INT
NO
ReadSigIndex
NRW
Index into the Signature Data
Array
88-113
SIG_DATAn
XDTB_
TECH
ARRAY
148
S_INT
[24]
/100
SigData
R
Signature Data Array
System Setup and Special Diagnostics Parameters
33
USER_INTER-
FACE_INSTANT
XDTB_
TECH
BIT_STRING
36
U_INT
NO
UI_Instant
R
Current hardware DIP switch
and GAIN control settings
– not applied to control
algorithms.
34
USER_INTER-
FACE_ACTIVE
XDTB_
TECH
BIT_STRING
37
U_INT
NO
UI_Saved
RW
Setup button and DIP switch
setting currently applied to
control algorithms
24
TEST_MODE
XDTB_
MAIN
BIT_STRING
32
U_CHAR
NO
control_
disable_flg
RW
Turns on and off special
diagnostic capabilities
62
TRAVEL_
ACCUM_UNITS
XDTB_
MAIN
UNSIGNED 8
150
U_CHAR
NO
TravelUnits
SRW
Setup, Units, Travel Distance
63
PRESSURE_
UNITS
XDTB_
MAIN
UNSIGNED 8
151
U_CHAR
NO
PressUnits
SRW
Setup, Units, Pressure
64
INTERNAL_
TEMP_UNITS
XDTB_
MAIN
UNSIGNED 8
152
U_CHAR
NO
TempUnits
SRW
Setup, Units, Temperature
65
XD_FSTATE_OPT
XDTB_
MAIN
UNSIGNED 8
153
U_CHAR
NO
Fail_mode
SRW
Sets fail state upon FF board
failure
66
ELECTRONICS_
SN
XDTB_
MAIN
VISIBLE_
STRING
155
U_CHAR
NO
ESN [8]
NR
Electronics Serial Number,
used for initial PD tag
67
SOFTWARE_
VER_MAJOR
XDTB_
MAIN
UNSIGNED 16
156
U_INT
NO
ESR_Major
NR
Software Revision Major
68
SOFTWARE_
VER_MINOR
XDTB_
MAIN
UNSIGNED 16
157
U_INT
NO
ESR_Minor
NR
Software Revision Minor
69
SOFTWARE_
DATE_CODE
XDTB_
MAIN
VISIBLE_
STRING
158
STRING
NO
ESR_Build [6]
SRW
Embedded Software Revision
Date Stamp
73
FB_POSI-
TION_FILTER
XDTB_
TECH
UNSIGNED 16
162
U_INT
NO
FB_Depth
SRW
Setup, Dampening, Position,
Depth
75
LOAD_EE_
DEFAULTS
XDTB_
TECH
UNSIGNED 8
173
U_CHAR
NO
EEmode
RW
Test, FRAM, Mode Setting
System Setup and Special Diagnostc Fieldbus Only Parameters
109
MAIN_BLOCK_
TEST
XDTB_
MAIN
ARRAY
N/A
N/A
N/A
N/A
R
Diagnostic Use Only
111
MAIN_EXEC_
DELAY
XDTB_
MAIN
UNSIGNED 16
N/A
N/A
N/A
N/A
SRW
Diagnostic Use Only
80
MD_BLOCK_
TEST
XDTB_MD
ARRAY
N/A
N/A
N/A
N/A
R
Diagnostic Use Only
81
MD_EXEC_
DELAY
XDTB_MD
UNSIGNED 16
N/A
N/A
N/A
N/A
SRW
Diagnostic Use Only
83-91
TREND_DATA_n
XDTB_MD
ARRAY
N/A
N/A
N/A
N/A
R
Trend Data
75
NVRAM_
WRITE_CYCLES
XDTB_
TECH
UNSIGNED 32
N/A
N/A
N/A
N/A
NR
Number of cycles that NVRAM
has been written to
76
GENERIC_
PARAMETER
XDTB_
TECH
GENERIC_S
N/A
N/A
N/A
N/A
RW
Used for reading and writing
data to control board registers
77
SPI_TEST_RCV
XDTB_
TECH
ARRAY
N/A
N/A
N/A
N/A
R
Diagnostic Use Only
78
SPI_TEST_TX
XDTB_
TECH
ARRAY
N/A
N/A
N/A
N/A
R
Diagnostic Use Only