Flowserve WR User Manual
Page 22

WR and CR USER INSTRUCTIONS ENGLISH 26999968 10-12
Page 22 of 28
flowserve.com
FAULT SYMPTOM
P u m p o v e r h e a t s a n d s e i z e s
⇓
⇓
⇓
⇓
B e a r i n g s h a v e s h o r t l i f e
⇓
⇓
⇓
⇓
P u m p v i b r a t e s o r i s n o i s y
⇓
⇓
⇓
⇓
M e c h a n i c a l s e a l h a s s h o r t l i f e
⇓
⇓
⇓
⇓
M e c h a n i c a l s e a l l e a k s e x c e s s i v e l y
⇓
⇓
⇓
⇓
P u m p r e q u i r e s e x c e s s i v e p o w e r
⇓
⇓
⇓
⇓
P u m p l o s e s p r i m e a f t e r s t a r t i n g
⇓
⇓
⇓
⇓
I n s u f f i c i e n t p r e s s u r e d e v e l o p e d
⇓
⇓
⇓
⇓
I n s u f f i c i e n t c a p a c i t y d e l i v e r e d
⇓
⇓
⇓
⇓
P u m p d o e s n o t d e l i v e r l i q u i d
⇓
⇓
⇓
⇓
POSSIBLE CAUSES
POSSIBLE REMEDIES
Bearings worn
Replace bearings.
Wearing ring surfaces worn.
Replace worn wear ring/surfaces.
Impeller damaged or eroded.
Replace or CONSULT FLOWSERVE for improved 
material selection. 
Leakage under sleeve due to joint failure.
Replace joint and check for damage.
Shaft sleeve worn or scored or running off centre.
Check and renew defective parts.
Mechanical seal improperly installed.
Check alignment of faces or damaged parts and 
assembly method used. 
Incorrect type of mechanical seal for operating 
conditions. 
CONSULT FLOWSERVE.
Shaft running off centre because of worn bearings or
misalignment.
Check misalignment and correct if necessary. If 
alignment satisfactory check bearings for excessive 
wear. 
Impeller out of balance resulting in vibration.
Check and CONSULT FLOWSERVE.
Abrasive solids in liquid pumped.
Internal misalignment of parts preventing seal ring and 
seat from mating properly. 
Mechanical seal was run dry.
Check mechanical seal condition and source of dry 
running and repair. 
Internal misalignment due to improper repairs causing
impeller to rub.
Check method of assembly, possible damage or 
state of cleanliness during assembly. 
Remedy or CONSULT FLOWSERVE, if necessary. 
Excessive thrust caused by a mechanical failure inside 
the pump. 
Check wear condition of impeller, its clearances and 
liquid passages. 
Excessive grease in ball bearings.
Check method of regreasing.
Lack of lubrication for bearings.
Check hours run since last change of lubricant, the 
schedule and its basis. 
Improper installation of bearings (damage during
assembly, incorrect assembly, wrong type of bearing 
etc). 
Check method of assembly, possible damage or 
state of cleanliness during assembly and type of 
bearing used. Remedy or CONSULT 
FLOWSERVE, if necessary. 
Damaged bearings due to contamination.
Check contamination source and replace damaged 
bearings. 
C. MOTOR ELECTRICAL PROBLEMS
Wrong direction of rotation.
Reverse 2 phases at motor terminal box.
Motor running on 2 phases only.
Check supply and fuses.
Motor running too slow.
Check motor terminal box connections and voltage.