FAULT SYMPTOM
Motor protection triggered
Pump does not start
Motor overheats
Unit runs but does not pump
Unit vibrates or is noisy
Motor loses filling liquid
Pump requires excessive power
Pump does not draw in water at start
Insufficient pressure developed
Insufficient capacity developed
PROBABLE CAUSES
POSSIBLE REMEDIES
A. System problems
Abrasive solids in liquid pumped.
Check and consult Flowserve.
Internal misalignment due to improper repairs
causing impeller to rub.
Check method of assembly, possible damage
or state of cleanliness during assembly.
Excessive thrust caused by a mechanical
failure inside the pump.
Check wear condition of impeller, its
clearances and liquid passages.
Improper installation of bearings.
Check method of assembly, possible damage
or state of cleanliness during assembly and
type of bearing used.
Damaged bearings due to contamination.
Check contamination source and replace
damaged bearings.
Slide valve not fully open.
Open slide valve.
Pressure pipe clogged. Foreign body in the
pipe line.
Clean pipe work.
Pump blocked by impurities inside the pump.
Disassemble pump section and clean.
Pump or motor sluggish.
Check smooth running of motor/pump.
Well filter clogged up.
Remove unit and regenerate well.
Coupling between pump and motor faulty.
Remove unit and repair.
Suction strainer clogged up.
Remove unit and clean suction strainer.
C. Electrical problems
Wrong direction of rotation of motor.
Reverse two phases at motor terminal box.
Motor circuit breaker incorrectly adjusted.
Readjust motor circuit breaker according to
data card or rating plate.
Motor running too slow. Under voltage or
wrong frequency.
Check if system voltage and frequency agree
with data sheet.
Phase failure.
Examine power cable for damage. Check
fuses.
Blown fuses.
Replace fuses.
Damaged power cables.
Replace power cables.