Transport and storage, Consignment receipt and unpacking, Handling – Flowserve Durco Mark 3 ISO Frame Mounted User Manual
Page 10: Lifting, Handling (2.2), Lifting (2.3), Receipt and unpacking (2.1), 2transport and storage, 1 consignment receipt and unpacking, 2 handling

DURCO MARK 3 ISO FRAME MOUNTED ENGLISH 85392719 12-14
Page 10 of 52
flowserve.com
Motor size
and speed
kW (hp)
Typical sound pressure level LpA at 1 m reference 20 μPa, dBA
3550 r/min
2900 r/min
1750 r/min
1450 r/min
Pump
only
Pump and
motor
Pump
only
Pump and
motor
Pump
only
Pump and
motor
Pump
only
Pump and
motor
<0.55 (<0.75)
58
65
50
58
50
52
50
52
0.75 (1)
60
65
52
59
51
54
51
54
1.1 (1.5)
62
67
54
60
55
57
53
56
1.5 (2)
63
66
55
63
56
59
54
58
2.2 (3)
64
69
57
65
58
62
56
60
3 (4)
63
71
58
68
59
64
57
62
4 (5)
64
72
60
69
61
65
59
63
5.5 (7.5)
66
73
62
71
63
67
61
65
7.5 (10)
67
73
63
71
64
69
62
67
11 (15)
69
76
65
73
66
71
64
69
15 (20)
71
77
67
74
68
72
66
70
18.5 (25)
72
78
68
75
69
70
67
70
22 (30)
73
78
69
76
70
71
68
71
30 (40)
75
79
71
77
72
72
70
72
37 (50)
76
80
72
78
73
73
71
73
45 (60)
77
81
73
79
74
74
72
74
55 (75)
78
81
74
79
75
75
73
75
75 (100)
80
83
76
81
77
76
75
76
90 (120)
81
84
77
81
78
77
76
77
110 (150)
82
85
78
82
79
78
77
78
150 (200)
84
87
80
84
81
79
79
79
200 (270)
①
①
①
①
81
81
79
79
300 (400)
–
83
86
81
82
The noise level of machines in this range will most likely be of values which require noise exposure control, but typical values are inappropriate.
Note: for 1 180 and 960 r/min reduce 1 450 r/min values by 2 dBA. For 880 and 720 r/min reduce 1 450 r/min values by 3 dBA.
2
TRANSPORT AND STORAGE
2.1
Consignment receipt and
unpacking
Immediately after receipt of the equipment it must be
checked against the delivery/shipping documents for
its completeness and that there has been no damage
in transportation. Any shortage and/or damage must
be reported immediately to Flowserve and must be
received in writing within one month of receipt of the
equipment. Later claims cannot be accepted.
Check any crate, boxes or wrappings for any
accessories or spare parts that may be packed
separately with the equipment or attached to side
walls of the box or equipment.
Each product has a unique serial number. Check
that this number corresponds with that advised and
always quote this number in correspondence as well
as when ordering spare parts or further accessories.
2.2
Handling
Boxes, crates, pallets or cartons may be unloaded
using fork lift vehicles or slings dependent on their
size and construction.
2.3
Lifting
A crane must be used for all pump sets or
components in excess of 25 kg (55 lb.). Fully trained
personnel must carry out lifting, in accordance with
local regulations.
Slings, ropes and other lifting gear should be
positioned where they cannot slip and where a
balanced lift is obtained. The angle between sling or
ropes used for lifting must not exceed 60°.
2.3.1
Bare pump
The bare pump should be lifted as shown: