Vise – Floscan FloNET Standard Flow Model User Manual
Page 9
![background image](https://www.manualsdir.com/files/784058/content/doc009.png)
06/02/2011
4001-443-00B
Forward Fuel Line Fitting to Forward Sensor Assembly
1. Leave the Pulsation Damper’s base clamped in the vise.
FloScan
VISE
Hex Flow
Straightener
Sensor
Body
Pulsation
Damper
Base
Fuel Line
Fitting
2. Coat the fuel line fitting’s ¼” MNPT threads with sealant.
3. Place the fitting into the Sensor’s Hex Flow Straightener.
4. Tighten hand tight.
5. Place an adjustable wrench on the Sensor’s Hex Flow
Straightener to act as a counter torque.
6. Use an adjustable wrench to tighten the fuel line fitting into
the Hex Flow Straightener.
7. Whenever possible, use a straight fitting on the Forward
Sensor’s inlet port. If required a 45° elbow fitting can be
used.
8. 90° elbow fittings on the Forward Sensor’s inlet port should
be avoided.
9. Determine which type of fitting is required for the Pulsation
Damper’s outlet port.
10. If the Pulsation Damper’s base is clamped in a vise, a
counter torque wrench is not required for the outlet fitting
assembly.
11. Straight, 45° or single 90° elbow fittings are each
acceptable at the forward Pulsation Damper’s outlet port.
12. The Pulsation Damper’s outlet port has ½” FMPT threads.
If a 90° elbow fitting is required, use a ½” elbow with ½”
MNPT threads.
• CAUTION: When tightening the forward fuel line fitting into the Forward Sensor’s Hex Flow Straightener, always place a
counter torque wrench on the Sensor’s Hex Flow Straightener.
• Never place a wrench on the Forward Sensor’s body while assembling the fuel line fitting into the Forward Sensor’s Hex
Flow Straightener. The Hex Flow Straightener is locked into place with a very strong retaining compound. It must remain in
position and must not be tightened or loosened. Moving the Hex Flow Straightener in relation to the Sensor body will
destroy the Sensors accuracy. Turned Hex Flow Straighteners are not considered warranty items.
CAUTION, DO NOT OVER TIGHTEN FLOW SENSOR FITTINGS. Over-tightening may crack the sensor’s body. Cracks
cause leaks, and fuel leaks sometimes cause catastrophic explosions and fire. Assemble fittings with a Lubricating, Fuel Proof,
Non or Semi Hardening pipe thread sealant, designed for aluminum and stainless steel threads, (Loctite 567 or equivalent).
DO NOT USE TEFLON TAPE.
(Continued on next page)
FloScan Instrument Company, Inc.
Tel:
(206)
524-6625
Fax:
(206)
523-4961
3016 NE Blakeley Street, Seattle, WA 98105
Email:
Http://www.floscan.com
- N20D-201-2K FloNET N20D-BOS-2K FloNET N20RBBOS-2K FloNET N20D0-2012K FloNET N20D-231-2K FloNET N20D0-BOS2K FloNET N20D0-2312K FloNET N20RB201-2K FloNET N2TD-235-2K FloNET FloNET Hi Capacity Flow Model N2TD-6DB-2K FloNET N20D-3CB-2K FloNET N2TD-6DC-2K FloNET N2TD-6DD-2K FloNET N2TRB6DB-2K FloNET N20RB3CB-2K FloNET N2TD-6CB-2K FloNET N2TRB6CB-2K FloNET N2TD0-6DD2K FloNET N2TD-6ED-2K FloNET N20D-3BB-2K FloNET N20D0-3EE2K FloNET N20D-3DC-2K FloNET N20D0-3BB2K FloNET N20D0-3CB2K FloNET N2TD0-6CB2K FloNET N2TD0-6ED2K FloNET N2TD-6GG-2K FloNET N2TD-6FD-2K FloNET N20D0-3ED2K FloNET N2TD-6CC-2K FloNET N2TD-6FE-2K FloNET N20D0-3DB2K FloNET N2TD0-6FE2K FloNET N2TD0-6BB2K FloNET N2TD-6BB-2K FloNET N2TD-6EE-2K FloNET