Vise, Mechanical assembly – Floscan FloNET Standard Flow Model User Manual
Page 8
![background image](https://www.manualsdir.com/files/784058/content/doc008.png)
06/02/2011
4001-443-00B
MECHANICAL ASSEMBLY
Standard Flow Diesel Systems (BOS, 201, 231 & 235-2K)
Forward Sensor to Forward Pulsation Damper Assembly
1. Clamp the Pulsation Damper’s aluminum base into a vise.
FloScan
VISE
Hex Flow
Straightener
Sensor
Body
Hex Reducer
Nipple
Pulsation
Damper
Base
2. Coat the Hex Reducer Nipple’s ½” MNPT threads with
sealant.
3. Place the ½” MNPT Hex Reducer Nipple threads into the
Pulsation Damper’s base end with the Inward Pointing
Arrow (Î).
4. Tighten hand tight.
5. Coat the Hex Reducer Nipple’s ¼” MNPT threads with
sealant.
6. Place the Forward Sensor’s “OUT” port onto the ¼”MNPT
Hex Reducer Nipple end.
7. Tighten hand tight.
8. Use an adjustable wrench to tighten the Hex Reducer Nipple
into the Pulsation Damper base.
9. Use an adjustable wrench to tighten the sensor body onto the
Hex Reducer Nipple. DO NOT put a wrench on the Forward
Sensor’s Hex Flow Straightener, at the Sensor’s inlet port
10. When tightened, the Sensor’s base and the Pulsation
Damper base must be even.
• CAUTION: When tightening the Forward Sensor onto the Hex Reducer, always place the wrench onto the Sensor’s body.
• Never place a wrench on the Forward Sensor’s Hex Flow Straightener while assembling the Sensor onto the Forward
Pulsation Damper. The Flow Straightener is locked into place with a very strong retaining compound and must remain in
position. It must not be tightened or loosened. Moving the Flow Straightener in relation to the Sensor body will destroy the
Sensors accuracy. Turned Flow Straighteners are not considered warranty items.
CAUTION, DO NOT OVER TIGHTEN FLOW SENSOR FITTINGS. Over-tightening may crack the sensor’s body. Cracks
cause leaks, and fuel leaks sometimes cause catastrophic explosions and fire. Assemble fittings with a Lubricating, Fuel Proof,
Non or Semi Hardening pipe thread sealant, designed for aluminum and stainless steel threads, (Loctite 567 or equivalent).
DO NOT USE TEFLON TAPE.
(Continued on next page)
FloScan Instrument Company, Inc.
Tel:
(206)
524-6625
Fax:
(206)
523-4961
3016 NE Blakeley Street, Seattle, WA 98105
Email:
Http://www.floscan.com
- N20D-201-2K FloNET N20D-BOS-2K FloNET N20RBBOS-2K FloNET N20D0-2012K FloNET N20D-231-2K FloNET N20D0-BOS2K FloNET N20D0-2312K FloNET N20RB201-2K FloNET N2TD-235-2K FloNET FloNET Hi Capacity Flow Model N2TD-6DB-2K FloNET N20D-3CB-2K FloNET N2TD-6DC-2K FloNET N2TD-6DD-2K FloNET N2TRB6DB-2K FloNET N20RB3CB-2K FloNET N2TD-6CB-2K FloNET N2TRB6CB-2K FloNET N2TD0-6DD2K FloNET N2TD-6ED-2K FloNET N20D-3BB-2K FloNET N20D0-3EE2K FloNET N20D-3DC-2K FloNET N20D0-3BB2K FloNET N20D0-3CB2K FloNET N2TD0-6CB2K FloNET N2TD0-6ED2K FloNET N2TD-6GG-2K FloNET N2TD-6FD-2K FloNET N20D0-3ED2K FloNET N2TD-6CC-2K FloNET N2TD-6FE-2K FloNET N20D0-3DB2K FloNET N2TD0-6FE2K FloNET N2TD0-6BB2K FloNET N2TD-6BB-2K FloNET N2TD-6EE-2K FloNET