IN-GROUND POST INSTALLATION (cont.)

Fig. 16-1 Connect gas

In-ground

method shown.

Individual setup

may vary.

CONNECT THE GAS SUPPLY

For household propane or natural gas units:

Route the fl ex connector to the gas stub.

Turn OFF the gas supply at the source. Remove the
adapter that is loosely connected to the fl ex connector.
Attach the adapter to the gas-supply stub using a pipe
compound resistant to all gasses. Tighten securely. Then
attach the open end of the fl ex connector to the adapter.
Tighten securely.

For propane cylinders:

For connecting a propane unit to a portable propane tank,
read the safety warnings and follow the instructions in the
section SAFE USE AND MAINTENANCE OF PROPANE
GAS CYLINDERS.

Important: An appropriate adapter will be required to

connect the existing fl ex connector to an
L.P. regulator/hose assembly.

LEAK TEST

Turn all burner control knobs to the OFF position. Turn the
gas supply on. Then carefully check all gas connections
for leaks with a brush and half-soap/half-water solution
before lighting. NEVER USE A MATCH OR OPEN
FLAME TO TEST FOR LEAKS.

RECONNECT POWER SUPPLY WIRES

CAUTION: IMPROPERLY CONNECTED WIRES WILL

CAUSE DAMAGE TO THE GRILL AND
MAY RESULT IN PROPERTY DAMAGE
AND/OR PERSONAL INJURY.

To connect the power supply box, connect the wires

coming from the power supply to the wire harness extension
as shown in Fig. 16-2.

Important: Apply dielectric grease to the male connectors

prior to making any wire connections.

RE-SECURE ACCESS PLATE

Carefully replace the access plate using the four screws,
ensuring all interior components are properly oriented
inside of the grill. Ensure the power supply cord (and fl ex
connector if applicable) coming out of the rear of the post
are properly situated and the plastic bushing/grommet
pieces are secure in place.

CONNECT POWER CORD

Plug the power supply cord into a properly wired,
grounded, and inspected GFCI electrical receptacle.
Use a heavy-duty grounded extension cord if necessary.

Note: Keep electrical supply cords away from all

heated surfaces.

Flex

connector

Gas

supply

line

Adapter

REV 0 - 1412011435

L-C2-436

Fig. 16-2 Connect: Wires, Plate, Power

To GFCI

receptacle

Wire

Connections

WARNING

Electrical Grounding Instructions:

This outdoor-cooking gas appliance is equipped
with a three-pronged (grounding) plug. Do not cut or

remove the grounding prong from the plug.