COUNTERTOP OVERHANG

The control panel is designed to sit fl ush against the enclosure front wall. If the non-combustible enclosure countertop extends
beyond the front wall, creating a countertop overhang, it must be cut fl ush with the front wall for the width of the control panel or
a gap will be created exposing the forward portions of the left and right side grill fi re walls. See illustrations above.

MODEL SPECIFICATIONS

Important:

FOR YOUR SAFETY, you must provide openings in the island enclosure for drainage, replacement air, and

cross-ventilation of any storage area exposed to possible leakage from gas connections, the unit, or propane

tanks. See the ENCLOSURE REQUIREMENTS section for details.

If equipped

*

Note: If installing this grill in a combustible enclosure, the correct insulating liner must be used. Consult liner instructions for

counter cut-out dimensions and installation.

Includes any substrate at front wall of enclosure (in the area the rear of the control panel is to sit fl ush against). See SUBSTRATE

section on next page.

Only applicable for non-combustible enclosures that have countertops with an overhang (see illustration and section below).

TOP VIEW

Countertop

Lower support

Countertop
overhang

Control panel

NON-COMBUSTIBLE

ENCLOSURE CUT-OUT

DIMENSIONS

Fig. 7-1

FRONT VIEW

B

C

D

Extra cut-out

for Power

Hood only!

1-

1

/

4

" x 10"

11"

See next page

for substrate

considerations

Countertop
overhang

X

TOP VIEW

SIDE VIEW

Countertop

overhang

(Control

panel)

(Countertop)

Y

1

/

4

"

Clearance

(Overhang)

X=

7

/

8

"

Y= Total
Countertop
Overhang

A

Control

panel

Check clearance for

control panel removal

MODEL SPECIFICATIONS TABLE

Table 1

E660i

E790i

E1060i

Main burner quantity
N/P orifi ce drill size

3

#42 / #54

3

#38 / #53

4

#40 / #53

Back burner quantity
N/P orifi ce drill size

1

#53 / #63

1

#51 / #57

2

#53 / #63

Smoker drawer burner
N/P orifi ce drill size

#68 / #77

#68 / #77

#68 / #77

Infrared searing burner

N/P orifi ce drill size

#45 / #55

#45 / #55

#45 / #55

Echelon insulating liner model # (not included)*

3176-50

3186-50

3185-50

Power Supply Rating

120VAC / 1.5A / 60 Hz

Oven Lights Rating

12V / 10 watt halogen light bulb

A Countertop to unit bottom cut-out*

12"

12"

12"

B Side to side non-combustible cut-out*

31-

1

/

4

"

37"

50"

C Front to back non-combustible cut-out*†

23-

1

/

2

"

23-

1

/

2

"

23-

1

/

2

"

D Control panel width non-combustible cut-out

33"

38-

3

/

4

"

51-

3

/

4

"

REV 5 - 1412081445