beautypg.com

Fireplace installation, Continued – Desa (V)T36ENA SERIES User Manual

Page 18

background image

111251-01D

For more information, visit www.desatech.com

For more information, visit www.desatech.com

18

FIREPLACE INSTALLATION

Continued

FIREPLACE INSTALLATION

Installing Optional Blower Accessories (Cont.)

Figure 29 - Blower Wiring Diagram for Thermostat-Controlled
Models

Blower Wiring Diagram

CAUTION: Label all wires prior to disconnection

when servicing controls. Wiring errors can cause
improper and dangerous operation. Verify proper
operation after servicing.

Blue

Variable

Fan Switch

Fan Switch

(N.O.)

Green

White

On

110/115

V.A.C.

Blower

Motor

Black

Off

1

2

Black

3.

Place the blower against the lower rear wall of the firebox outer
wrapper with the exhaust port directed upward and the thermodisc
positioned up near the fireplace bottom. The thermodisc must be
oriented near the fireplace bottom as shown in Figure 28 in order
to sense temperature and properly operate. The blower will be
held in position against the back wall by the magnets incorpo-
rated onto the blower housing (see Figure 28).

4.

Be certain that all wire terminals are securely attached to ter-
minals on blower motor and thermal switch, and that the screw
for the thermodisc bracket and green ground wire is tight.

5.

Mount the speed control box against the mounting plate pro-
vided in the lower fireplace cavity by placing the plastic control
shaft forward through the round hole (see Figure 26, page 17).

6.

While supporting speed control, secure control shaft with lock
nut by pushing and turning lock nut with pliers clockwise un-
til it is tight against mounting plate. Place control knob pro-
vided on shaft (see Figure 26, page 17).

7.

Check to make sure that the power cord is completely clear of the
blower wheel and that there are no other foreign objects in blower
wheel. Also double check all wire leads and make sure wire rout-
ing is not pinched or in a precarious position. Correct accordingly.

8.

Turn on power to duplex outlet if previously turned off per the
warning in column 2, page 16.

9.

Plug in blower power cord to duplex outlet.

10. The blower will only run when the speed control knob is in the

ON position and the thermal switch senses temperature after
the fireplace begins to heat up. The blower speed can be ad-
justed by rotating the control knob. To turn off, turn knob fully
counterclockwise until it clicks off. If the blower is ON and
has been running with the fireplace operating, the blower will
continue to run for a short time after the fireplace has been
turned off. As the thermal switch cools down, the blower shuts
down automatically.

11. Peel off the backing paper and stick the supplied wiring dia-

gram decal on the firebox bottom approximately 12" in front
of the blower (see Figure 27, page 17).

Thermodisc

Figure 28 - Blower Model BKT

Air Flow Direction

Route BKT
Blower Through
This Area

Magnets

Blower
Location

Side View Firebox Bottom

Black
Wire

Phillips
Screw

Blue Wire

Ring Terminal
on Green Wire

White Wire

Thermal Switch

Thermal
Switch
Bracket

Power Cord

Air Flow
Direction

Magnetic
Strips