GROUND FLOOR INSTALLATION

Recommended Applications:
• Installation using cabinet surrounds
• Through the wall using round or square termination (up to 12"

horizontal pipe)

• NOT FOR CORNER INSTALLATION

VENTING INSTALLATION
INSTRUCTIONS

Continued

VENTING INSTALLATION INSTRUCTIONS

Installation Planning (Cont.)

Horizontal Termination Configurations

Figures 14 through 18 show different configurations and alternatives
for venting with horizontal termination. Each figure includes a chart
with critical minimum and maximum dimensions which MUST be
met. IMPORTANT: Remember that a horizontal run of venting must
have a 1/4" rise for every 12" of run toward the termination.

Figure 13 - Typical Horizontal Termination Cap Mounting with
Additional Siding Standoff Installed

Siding Standoff

Screws

High Wind
Termination

Apply Mastic to
Outside Edge of
Standoff

Exterior Wall
with Vinyl Siding

10" x 10"
Framed
Opening

Maintain 1"
Minimum Air
Space Around
Outer Pipe When
Penetrating a Wall

Minimum Pipe
Overlap 1

1

/

4

"

Wall
Firestop

Direct Vent
Pipe

WARNING: Never run vent downward as this may

cause excessive temperatures which could cause a
fire. Operation of improperly installed and main-
tained venting system could result in serious injury,
property damage or loss of life.

Horizontal High
Wind Square
Termination

Wall Firestop

45° Elbow

Adjustable
Pipe 12" Max.

Vertical (V)

Horizontal (H)

32" min.

17" max.

Square Termination

Figure 14 - Horizontal Termination Configuration for Square and
Round Terminations

45° Elbow

Wall
Firestop

Round
Termination
Cap

Exterior Portion of Wall
Firestop (Round
Termination Only)

Round Termination
(Kit HTK Shown)

Slide Ring
Over Elbow to
Complete
Connection