The following events can be monitored. For information about selecting which events to monitor, see the
“Organization” section of this manual.

Camera Events

Definition

Video Loss

Analog or IP video signal lost.

Video Motion

Camera has detected motion.

Camera Disconnected

Network cannot connect to analog or IP camera.

Server Events

Definition

Archive Alarm

Failure on archiving target, such as bad mount point.

Archive Task Alarm

Archive task failed.

Button Press

Button input on server pressed.

Content Age Alarm*

Video deleted before configured retention period. For example, the server
is configured to retain video for 30 days, but the server does not have
enough space to store that much video.*

Core Throttling

Server load requires that video frames be discarded to compensate.

DVR Board Failure

Capture card malfunctioned.

DVR Board Temperature

Capture card temperature not within recommended range.

Fan Alarm

Fan has failed on capture board

Fanspeed sensor alarm

System fan not operating at recommended speed.

Input Trigger

Discrete input on a hybrid server (or IP camera with alarm input) activated.

Login Failure

Login attempt failed on server.

Power Supply Alarm

Alarm on a server with redundant power supply.

Server Disconnected

Connection to server lost.

Server License Error

Invalid license on server.

Server License Warning

License will expire in less than 30 days.

Soft Trigger

Signal sent from Client to server.

Storage Alarm

Drive capacity threshold reached.

Storage Hardware Alarm

Server storage malfunctioned.

Temperature Sensor Alarm

System temperature not within recommended range.

Update Downloading

Software update download in progress.

Update Failure

Server software update failed.

Update Installing

Server software update installing.

Update Pending

Server restarting after software update.

Update Success

Server software update completed.

Voltage Sensor Alarm

System voltage not in recommended range.

*When a new system starts recording video for the first time, a content age alarm will not be triggered even
though the age of the oldest recorded video is lower than the desired oldest content. This event cannot be
triggered until the system automatically deletes data when the storage capacity is filled earlier than desired.

For information about troubleshooting Content Age Alarm events, see https://crm.exacq.com/kb/?kbid=64975.