beautypg.com

Electro-Chemical Devices (ECD) DCA-23 User Manual

Page 8

background image

Page 2

DCA-23 Dechlorination Analyzer

1.1 Features

Uni Strut Rail Mounted System, Easy Installation

Plumb and Play Design, Ready to Use

Not Flow Sensitive, Eliminates Pressure Regulators and Rotameters

Direct Chlorine Readout, pH and Temperature compensated

1.2 Specifications

Sensor and Flow Train

TRO Sensor:

Platinum Indicator/Silver-Silver chloride Reference, PTFE junction

0.75” OD x 10.5” length, Internal Signal Conditioning

pH Sensor:

Glass Indicator/Silver-Silver chloride Reference, PTFE junction

0.75” OD x 10.5” length, Internal Signal Conditioning

Measurement Range:

Chlorine:

0.00 to 2.00 ppm

pH:

0 to 14 pH

Operating Temperature:

0° C to 60° C (32° F to 140° F)

Operating Pressure:

0-50 psig at 60° C

Wetted Materials:

PVC, PP, PTFE, Glass, Platinum, 316 SS

Process Connections:

Input: ¾” NPT Slip fitting,

Drain: ¾” NPT Slip fitting

Response Time:

T90 in 2 minutes

C22 Analyzer:

Measurements:

Chlorine:

0.01 to 2.00 ppm

pH:

0 to 14 pH

Temperature:

0° C to 100° C (32° F to 212° F)

pH Compensation:

Automatic

Display:

4” X 1” LCD, 2 x 16 characters

Enclosure:

NEMA 4X, LxWxD: 5.7” x 5.7” x 7

Outputs:

(1) 4-20 mA for Chlorine (set to Sensors Range, 0-2.00 ppm or 0-1.00 ppm)