BF39STP, BF39DXP


If the fireplace was operating prior to servicing allow at least 10 minutes for light bulbs
and heating elements to cool off to avoid accidental burning of skin.

Disconnect circuit power before attempting any maintenance or cleaning to reduce the
risk of electric shock or damage to persons.

TO REPLACE BLOWER MOTOR / BLOWER
(UNIT IS PERMENANTLY INSTALLED IN WALL)

1. Remove the log grate retaining screws and remove the log grate.

2. Pull the rear edge of the log set forward by grasping the ember bed by the sides

(handle the log set only by the ember bed and not the logs) and pulling firmly
until the rear tab pops out from under the back ledge, then lift out.

3. Release the steel curtains from the side panels by opening the retainers on the

sides of the fireplace using needle nose pliers.

4. Remove the steel curtains by lifting up on the curtain mounting rod releasing it

from the side mounting tab, and pulling out.

5. Remove the heater cover mounting screws from inside the firebox and remove

the heater cover by lifting it up from the back, bowing it slightly in the center and
pulling out by one end.

6. Properly orientate the replacement blower assembly and connect all of the wiring

connections in their original locations.

7. Reassemble in the reverse order as above.

NOTE:

To replace the log set re-connect the logset LED wire harness to the unit,

insert the front edge, pushing back down until the rear tab snaps under the back
ledge and the logs are resting against the mirror.