BF33STP, BF33DXP, BF39STP, BF39DXP
If the fireplace was operating prior to servicing allow at least 10 minutes for light bulbs
and heating elements to cool off to avoid accidental burning of skin.
Disconnect circuit power before attempting any maintenance or cleaning to reduce the
risk of electric shock or damage to persons.
TO REPLACE HEATING ELEMENTS
(UNIT CAN BE REMOVED FROM WALL)
NOTE:
The fireplace is equipped with two heating elements. The same removal &
installation instructions apply to both elements.
1. Remove unit from installed wall. (remove trim surround if applicable)
2. Remove a total of 4 screws from both side trims on unit.
3. Remove top panel mounting screws and position heater assembly upright being
careful not to damage any wires.
4. Locate the elements mounted to the top cover and disconnect the connections
noting their original locations.
5. Remove the 2 element cover hex head screws using a ⅜” hex head socket.
6. Remove the 3 remaining element cover mounting screws and remove element.
7. Properly orientate the replacement element and connect all of the wiring
connections in their original locations.
8. Reassemble in the reverse order as above.