beautypg.com

DR Power Hydraulic 8-Ton User Manual

Page 28

background image

28

8-TON DR

®

WOOD SPLITTER

S

YMPTOM

P

OSSIBLE

C

AUSE

Engine smokes.

(Please refer to the
engine owner’s
manual for engine-
specific procedures.)

⇒ Check the oil level and adjust as needed.
⇒ Check the air filter and clean or replace if needed.
⇒ You may be using the wrong oil—too light for the temperature. Refer to your

Engine Owner’s Manual for detailed information.

⇒ Clean the cooling fins if they’re dirty.

If the engine still smokes, contact us at www.DRpower.com or call 1(800) DR-
OWNER (376-9637)
for assistance.

The engine stalls
when the push plate
engages the wood.

⇒ The engine may not be properly adjusted. Contact us at www.DRpower.com or call

1(800) DR-OWNER (376-9637) for assistance.

The pusher plate
moves slowly, but
will split wood.

⇒ Check the hydraulic fluid level in the hydraulic tank and fill if necessary.

Check the high-pressure hose, fittings, and valve openings for dirt and debris that
may have obstructed the openings.

The ram will not
automatically
retract.

⇒ Check the slide rail or push plate for damage.
⇒ Push the valve control handle to the retract position. If the handle will not stay in

this position, contact us at www.DRpower.com or call 1(800) DR-OWNER (376-
9637)
for assistance.

Hydraulic fluid
squirts from the fill
plug during
operation.

⇒ The hydraulic fluid tank may be over-filled. Drain fluid down to the overflow screw.
⇒ The WOOD SPLITTER is not level. Make sure the WOOD SPLITTER is on level

ground.