2. Location

EN

20 cm

90 cm

15-25

cm

60 cm

• The detector should preferentially be at-

tached to the ceiling in the middle of the room.

Otherwise, attach it more than 20cm from any

obstacle (partition wall, beam, etc.) and over

60cm from any room corner.

• If this is impossible, attach the detector to

the wall at a distance of between 15 and 25cm

from the ceiling.

• In the case of an angled ceiling, attach the

detector at a location between 20 and 90 cm

vertically below the highest point.

In the home:

In the room:

Recommended locations:

• For enhanced protection:

- Place a detector in each room, avert using listed places to avoid.

• For basic protection:

- Place a detector on each floor.

- Place a detector close to sleeping areas

(for example, in the corridor leading to rooms; in the case

of a long corridor > 10m, place 1 detector at each end).

- Place a detector in each bedroom occupied by a smoker.

Flat

House

Dining

room

Kitchen

Bedroom

Smoker
bedroom

Lounge

Bedroom

Basic protection

Enhanced protection

Bedroom

Bedroom

Lounge

Kitchen

Basement

Corridor