1. Presentation

2. Location

Locations to avoid

Do not install the detector:
• Within a metre from vents for heating, cooling or circulating air.

The smoke could be blown away from the detector or be diluted.
• In a place where the temperature could drop beneath 0°C or rise above

+50°C;

risk of detector not working correctly.
• In a place where there is a risk of condensation. Bathrooms and laundry

rooms are not recommended.
• Places where smoke could gather (kitchen or poorly ventilated garage)

and cause false alarms.
• In a place that is excessively dusty.

Additional installation recommendations, as well as the "Manda-
tory Performance Declaration" for this equipment are available in
the product fi le for DFR TYXAL+ on our website www.deltadore.com
Material manufactured by SHD BP10809 under reference DFR
TYXAL+.

You must check that your detector is functional once

a month or after each battery change.

Pressing the "test" button on the case for a few

seconds will light up the LED and the detector will

emit 2 beeps.

Do not try to trigger the alarm any other way (using a lighter, etc.) because

you could damage the detector or even start a fi re.

Your detector has been designed to require the minimum maintenance pos-

sible. However, some simple actions need to be performed once a year.

After having removed the detector:

• Clean the cracks in the detector (located on the side) with a vacuum

cleaner, using a soft brush or a vacuum cleaner accessory.
• Use a slightly damp cloth to clean the outside of the case.

Functional check and maintenance:

4

OK

2

1

3

>3s

It is recommended that the detector be replaced after 10 years.

EN

The detector can be associated with a DELTA DORE wireless X3D
alarm and control system.