beautypg.com

Troubleshooting, Continued, Problem possible cause remedy – DC Power Technologies FS5 - Owners Manual User Manual

Page 16

background image

16

Problem

Possible Cause

Remedy

Low Output Current

Only one battery cable
connected (FS9).

Ensure two battery cables are
connected (FS9 only).

Over Discharged Battery

Battery is <1.9Vpc at
connection but recovers within
30 seconds of charge.

Allow approximately 1 minute
between truck-battery
disconnect and charger-battery
connect. Regular occurrences
might need investigation of
work practices.

No Output Current

Battery unplugged during
charge.

Charge profile allows current to
fall below 0.7A

Ensure battery has not been
unplugged before charge
completion.
Check that the charge profile is
appropriate for the battery type.

Deeply Discharged Battery

Battery is still <1.9Vpc after 30
seconds of charge.

Check battery for faults.

Incorrect Battery

Battery is not the correct
voltage for the charger.

Check the configuration
matches the battery.

Bulk Charge Timeout

The bulk charge part of the
cycle is longer than expected.

Check the charger
configuration matches the
battery, check the battery for
problems.

Finishing Charge Timeout

The finishing charge part of the
cycle is longer than expected.

Check that the charger
configuration matches the
battery, regular timeouts may
indicate a problem with the
battery.

Battery Disconnected

Battery has been disconnected
during charge cycle.

Front panel toggle switch
must be set to STOP before
disconnecting battery.

Reversed Battery

A reverse polarity battery has
been connected to the charger.

Correct the incorrect battery
wiring and replace the blown
charger output fuse(s).