CALL COMPLETION


Once Pal rings the Extension Port, it continues to monitor the call. When the call is completed, Pal will
hang-up the phone line and wait for the next call. Pal’s Power setting will remain in its last position.
Optionally, Pal can be set to automatically turn power off on Outlet 1 after a preset time (0 to 90 seconds).
Use this setting to automatically shut down equipment when the call is complete. A typical application
would be to turn off a PC when the modem call to that PC is finished. If the power is off when the call is
terminated, this setting is ignored.

SECURITY


Additional security can be added to Pal’s power control and extension ringing features. With security
enabled, an additional code is required before gaining access to the power control. Once the code is
received, Pal will respond with the Ready prompt (three short beeps). The security code can be from one
to six digits long.

The security feature can be set for just power control, or both the power control and extension ring
functions.

When set for Power Only; all callers have unrestricted access to the extension, while a code is required
for power control. When set for Both Power and Extension; security code is required for all Pal functions.

If an incorrect security code is entered, Pal will send a low Error tone and wait for a second attempt. If the
second attempt is incorrect, or if no security code is entered at all, Pal will ring the extension (Power
Only), or hang up (Power and Extension Secure).


OPERATION SUMMARY

Command

Code

Remarks

Select Outlet

1 or 2

Pal responds with power status
1 Beep = Off, 2 = On
Power does not change.

Power Toggle

#

Power Changes and new status
is reported

Power Cycle

*

Power is Cycled for preset time.
(Programmable from 5 to 45