7 unit exchange/replacement procedure, 7unit exchange/replacement procedure -7 – Daktronics G-100-7.6-R User Manual
Page 27

Maintenance and Troubleshooting
4-7
Power Supplies
A-1499
Buzzer DS-1357
120V Transformer
T-1072
Fuse, MDL-7
F-1031
Power Cord
W-1181
Module Ribbon Cable
W-1362
Controller Ribbon Cable Set
2 Line Display
3 Line Display
4 Line Display
5 Line Display
6 Line Display
0A-1156-0069
0A-1156-0070
0A-1156-0071
0A-1156-0072
0A-1156-0073
“Door Split” Ribbon Cable Set
2 Line Display
3 Line Display
4 Line Display
5 Line Display
6 Line Display
0A-1156-0074
0A-1156-0075
0A-1156-0076
0A-1156-0077
0A-1156-0078
Signal Converter
0A-1127-0237
Signal Converter Serial Cable
W-1363
Serial Server
A-1557
LAN Patch Cable
W-1383
PC DB9-RJ11
0A-1115-0042
PC DB25-RJ11
0A-1115-0044
25’ RJ-11 Cable
W-1265
100’ RJ-11 Cable
0A-1146-0002
500’ RJ-11 Cable
0A-1146-0003
1000’ RJ-11 Cable
0A-1146-0004
Six Conductor Signal Wire
W-1368
RJ-11 Connector
P-1071
Crimp Tool
TH-1033
Cable Tester
0A-1146-0005
Venus 1500 Manual
ED-12717
Temperature Sensor
0P-1151-0003
Temperature Sensor Cable
W-1234
4.7
Unit Exchange/Replacement Procedure
Daktronics unique exchange program offers our clients the quickest, most economical way of
receiving product repairs. If a component fails, Daktronics will send the customer a
replacement. The customer, in turn, sends the failed component to Daktronics. This not only
saves money but decreases the time the display is inoperable. Daktronics offers repair and
return on a timely basis; in urgent situations, every attempt is made to ship by the fastest
transit method available.
1. Packaging for Return: Package and pad the item well to prevent damage during
shipment. Electronic components, such as printed circuit boards, should either be
installed in an enclosure or placed in an anti-static bag before boxing.
Please enclose your name and address along with a list of all the symptoms. Please be as
specific as possible.