beautypg.com

Troubleshooting – Desa LMFP33PR User Manual

Page 27

background image

www.desatech.com

111604-01E

27

TROUBLESHOOTING

Continued

POSSIBLE CAUSE

1. Metal expanding while heating

or contracting while cooling

1. Heater burning vapors from

paint, hair spray, glues, clean-
ers, chemicals, new carpet,
etc. (See

IMPORTANT

state-

ment on page 26)

2. Low fuel supply (propane/LP

only)

3. Gas leak. See Warning state-

ment on page 26

1. Not enough fresh air is available

2. Low line pressure

3. ODS/pilot is partially clogged

1. Gas leak. See Warning state-

ment on page 26

2. Control valve or gas control

defective

1. Foreign matter between con-

trol valve and burner

2. Gas leak. See Warning state-

ment at top of page 26

1. Improper log placement

2. Drafts or other air currents

affecting flame pattern

3. Air holes at burner inlet

blocked

4. Burner flame holes blocked

REMEDY

1. This is common with most heat-

ers. If noise is excessive, con-
tact qualified service person

1. Open window to ventilate

room. Stop using odor caus-
ing products while heater is
running

2. Refill supply tank (propane/LP

only)

3. Locate and correct all leaks

(see Checking Gas Connec-
tions
, page 16)

1. Open window and/or door for

ventilation

2. Contact local natural or pro-

pane/LP gas company

3. Clean ODS/pilot (see Cleaning

and Maintenance, page 23)

1. Locate and correct all leaks

(see Checking Gas Connec-
tions
, page 16)

2. Replace control valve or gas

control

1. Take apart gas tubing and re-

move foreign matter

2. Locate and correct all leaks

(see Checking Gas Connec-
tions
, page 16)

1. Properly locate logs (see In-

stalling Logs, pages 17 and 18)

2. Eliminate source of drafts

around heater

3. Clean out air holes at burner

inlet. Periodically repeat as
needed

4. Remove blockage

OBSERVED PROBLEM

Fireplace produces a clicking/
ticking noise just after burner is
lit or shut off

Fireplace produces unwanted
odors

Fireplace shuts off in use (ODS
operates)

Gas odor even when control knob
is in OFF position

Gas odor during combustion

Dark residue on logs inside of
their fireplace

Note:

After re-

moving all causes of residue
deposits, completely clean fire-
place and appliance off residue
before reusing appliance