beautypg.com

Troubleshooting – Desa LMFP33PR User Manual

Page 25

background image

www.desatech.com

111604-01E

25

OBSERVED PROBLEM

ODS/pilot lights but flame goes
out when control knob is released

Burner does not light after ODS/
pilot is lit

Delayed ignition of one or both
burners

Burner backfiring during com-
bustion

Slight smoke or odor during ini-
tial operation

POSSIBLE CAUSE

1. Control knob not fully pressed in
2. Control knob not pressed in

long enough

3. Equipment shutoff valve not

fully open

4. Pilot flame not touching ther-

mocouple, which allows ther-
mocouple to cool, causing pi-
lot flame to go out. This prob-
lem could be caused by one or
both of the following:
A) Low gas pressure
B) Dirty or partially clogged
ODS/pilot

5. Thermocouple connection

loose at control valve

6. Thermocouple damaged
7. Control valve damaged

1. Inlet gas pressure is too low

2. Burner orifice(s) clogged

3. Thermopile leads disconnected

or improperly connected

4. Burner will not come on in

remote position

1. Manifold pressure is too low

2. Burner orifice(s) clogged

1. Burner orifice is clogged or

damaged

2. Damaged burner
3. Gas regulator defective

1. Not enough air

2. Gas regulator defective
3. Residues from manufacturing

processes and logs curing

REMEDY

1. Press in control knob fully
2. After ODS/pilot lights, keep con-

trol knob pressed in 30 seconds

3. Fully open equipment shutoff

valve

4. A) Contact local natural or

propane/LP gas company

B) Clean ODS/pilot (see
Cleaning and Maintenance,
page 23) or replace ODS/pi-
lot assembly

5. Hand tighten until snug, then

tighten 1/4 turn more

6. Replace pilot assembly
7. Replace control valve

1. Contact local natural or pro-

pane/LP gas company

2. Clean burner(s) (see Cleaning

and Maintenance, page 23) or
replace burner orifice(s)

3. Reconnect leads (see Wiring

Diagram, page 28)

4. Replace battery in transmitter

and receiver

1. Contact local natural or pro-

pane/LP gas company

2. Clean burner(s) (see Cleaning

and Maintenance, page 23) or
replace burner orifice(s)

1. Clean burner (see Cleaning

and Maintenance, page 23) or
replace burner orifice(s)

2. Replace damaged burner
3. Replace gas regulator

1. Check burner for dirt and de-

bris. If found, clean burner
(see Cleaning and Mainte-
nance
, page 23)

2. Replace gas control
3. Problem will stop after a few

hours of operation

TROUBLESHOOTING