CHECKING GAS CONNECTIONS

WARNING: Test all gas pip-

ing and connections, internal
and external tonit, for leaks after
installing or servicing. Correct
all leaks at once.

WARNING: Never use an

open flame to check for a leak.
Apply a noncorrosive leak de-
tection fluid to all joints. Bubbles
forming show a leak. Correct all
leaks at once.

CAUTION: Make sure exter-

nal regulator has been installed
between propane/LP supply and
fireplace. See guidelines under
Connecting Fireplace to Gas
Supply, page 15.

Pressure Testing gas Supply Piping
System

Test Pressures In Excess Of 1/2 PSIG (3.5 kPa)

1.

Disconnect fireplace with its appliance main
gas valve (control valve) and equipment
shutoff valve from gas supply piping system.
Pressures in excess of 1/2 psig will damage
fireplace regulator.

2.

Cap off open end of gas pipe where equip-
ment shutoff valve was connected.

3.

Pressurize supply piping system by either
opening propane/LP supply tank valve for
propane/LP gas or opening main gas valve lo-
cated on or near gas meter for natural gas, or
using compressed air.

4.

Check all joints of gas supply piping system.
Apply noncorrosive leak detection fluid to all
joints. Bubbles forming show a leak.

5.

Correct all leaks at once.

6.

Reconnect fireplace and equipment shutoff
valve to gas supply. Check reconnected fit-
tings for leaks.

INSTALLATION

Continued

Test Pressures Equal To or Less Than 1/2 PSIG
(3.5 kPa)

1.

Close equipment shutoff valve (see Figure 23).

2.

Pressurize supply piping system by either
opening propane/LP supply tank valve for
propane/LP gas or opening main gas valve lo-
cated on or near gas meter for natural gas, or
using compressed air.

3.

Check all joints from gas meter to equipment
shutoff valve for natural gas or propane/LP
supply to equipment shutoff valve for propane/
LP (see Figures 24 or 25). Apply noncorro-
sive leak detection fluid to all joints. Bubbles
forming show a leak.

4.

Correct all leaks at once.

Figure 23 - Equipment Shutoff Valve

ON

POSITION

OFF

POSITION

Open

Closed

Equipment
Shutoff
Valve

Figure 25 - Checking Gas Joints for

Propane/LP Gas

Gas Control Valve

Figure 24 - Checking Gas Joints for

Natural Gas

Equipment
Shutoff
Valve

Gas Meter

Equipment Shutoff Valve

Gas Control Valve

Propane/LP
Supply Tank