Environmental – Comtech EF Data DST User Manual
Page 13

Digital Satellite Terminal System
Revision 2
Preface
MN/DST.IOM
ix
E
LECTRICAL
S
AFETY
The DST Digital Satellite Terminal System has been shown to comply with the following safety
standard:
• EN 60950: Safety of Information Technology Equipment, including electrical business
machines.
The equipment is rated for operation over the range 85 to 264 volts AC. It has a maximum
power consumption of 60 watts.
F
USES
The DST is fitted with two fuses, one each for line and neutral connections. These are contained
within the body of the IEC power connector, behind a small plastic flap.
IMPORTANT
For continued operator safety, always replace the fuses with the
correct type and rating. Refer to the SDM /CiM manual.
Environmental
The DST must not be operated in an environment where the unit is exposed to extremes
of temperature outside the ambient range 0 to 50°C (32 to 122°F), precipitation,
condensation, or humid atmospheres above 95% RH, altitudes (un-pressurised) greater
than 2000 metres, excessive dust or vibration, flammable gases, corrosive or explosive
atmospheres.
Operation in vehicles or other transportable installations that are equipped to provide a
stable environment is permitted. If such vehicles do not provide a stable environment,
safety of the equipment to EN60950 may not be guaranteed.