Breakout Panel

Revision 2

Connectors and Switches

MN/UB530.IOM

2–2

2.1 Switches

The five configuration DIP switches located on the rear of the breakout panel are used for
selecting IBS/IDR modes of operation, and balanced or unbalanced signals, and control
of D&I looping.

The RS-422 multi-functional connector (J2) on the front panel may be used for standard
(non-overhead), IBS, or IDR (ESC) mode. SW1, SW2, and SW3 are used in selecting
IBS or IDR mode of operation.

SW4 and SW5 are used to select balanced or unbalanced inputs and outputs.

Refer to Table 2-1 for UB-530 configuration switch settings. The locations of the
switches are shown in Figure 2-1.

Table 2-1. UB-530 Configuration Switch Selections

Switch

ON (Down) Position

OFF (Up) Position

SW1-All IBS

IDR

SW2-All IDR

IBS

SW3-All IBS

IDR

SW4-All

Unbalanced Data & Clock

Balanced Data & Clock

SW5-1

Unbalanced EXT Clock

Balanced EXT Clock

SW5-2

Unbalanced EXT Clock

Balanced EXT Clock

SW5-3

Drop out/Insert in loop

Drop out/Insert in normal

SW5-4

Drop out/Insert in loop

Drop out/Insert in normal

2.2 Connectors

The locations of the connectors are shown in Figure 2-1. Refer to Table 2-2 for a list of
UB-530 connectors.

Table 2-2. UB-530 Breakout Panel Connectors

Ref. Desig.

Type

Interface Function

J1

50-pin D socket

Modem DATA I/O

J2

37-pin D socket

RS-422 or 8 kbps ESC (IDR)

J3

25-pin D socket

V.35 or RS-530

J4

25-pin D socket

ESC

J5

25-pin D socket

Alarms (IBS and IDR)

J6

9-pin D socket

ADPCM Audio

J7

BNC

Unbalanced Drop Data Input/SD

J8

BNC

Unbalanced Insert Data Output/RD

J9

BNC

Unbalanced Drop Data Output

J10

BNC

Unbalanced Inset Data Input

J11

BNC

Unbalanced External Clock

J12

15-pin D socket

Balanced G.703