Switches, Connectors, 1 switches – Comtech EF Data UB-530 User Manual
Page 14: 2 connectors
Breakout Panel
Revision 2
Connectors and Switches
MN/UB530.IOM
2–2
2.1 Switches
The five configuration DIP switches located on the rear of the breakout panel are used for
selecting IBS/IDR modes of operation, and balanced or unbalanced signals, and control
of D&I looping.
The RS-422 multi-functional connector (J2) on the front panel may be used for standard
(non-overhead), IBS, or IDR (ESC) mode. SW1, SW2, and SW3 are used in selecting
IBS or IDR mode of operation.
SW4 and SW5 are used to select balanced or unbalanced inputs and outputs.
Refer to Table 2-1 for UB-530 configuration switch settings. The locations of the
switches are shown in Figure 2-1.
Table 2-1. UB-530 Configuration Switch Selections
Switch
ON (Down) Position
OFF (Up) Position
SW1-All IBS
IDR
SW2-All IDR
IBS
SW3-All IBS
IDR
SW4-All
Unbalanced Data & Clock
Balanced Data & Clock
SW5-1
Unbalanced EXT Clock
Balanced EXT Clock
SW5-2
Unbalanced EXT Clock
Balanced EXT Clock
SW5-3
Drop out/Insert in loop
Drop out/Insert in normal
SW5-4
Drop out/Insert in loop
Drop out/Insert in normal
2.2 Connectors
The locations of the connectors are shown in Figure 2-1. Refer to Table 2-2 for a list of
UB-530 connectors.
Table 2-2. UB-530 Breakout Panel Connectors
Ref. Desig.
Type
Interface Function
J1
50-pin D socket
Modem DATA I/O
J2
37-pin D socket
RS-422 or 8 kbps ESC (IDR)
J3
25-pin D socket
V.35 or RS-530
J4
25-pin D socket
ESC
J5
25-pin D socket
Alarms (IBS and IDR)
J6
9-pin D socket
ADPCM Audio
J7
BNC
Unbalanced Drop Data Input/SD
J8
BNC
Unbalanced Insert Data Output/RD
J9
BNC
Unbalanced Drop Data Output
J10
BNC
Unbalanced Inset Data Input
J11
BNC
Unbalanced External Clock
J12
15-pin D socket
Balanced G.703