beautypg.com

2 drop data output (j2) – Comtech EF Data D&I User Manual

Page 18

background image

D&I

Revision 0

Connectors ans Switches

MN/D-I.IOM

2–6

2.1 Drop Data Input, Insert Data Output, and Ext. Ref CLK

This signal connection is a 15-pin female D connector (J1) located at the front of the
breakout panel. Screw locks are provided for mechanical security of the mating
connector.

Signal Function

Name

Pin #

Ground GND

2,

4

Insert Data Out

IDO–A
IDO–B

3
11

External Clock

EXC–A
EXC–B

7
8

Drop Data Input

DDI–A
DDI–B

1
9


For J1 selections, use S1, S2, and S3, located at the rear of the breakout panel.

Signal Function

Name

Switch

Switch #

Position

Balanced Insert Data Output

IDO

S2

5, 6/7, 8

ON/OFF

Balanced Drop Data Input

DDI

S1

1, 2/3, 4

ON/OFF

Balanced External Clock

EXC

S3

1, 3/2, 4

ON/OFF

2.2 Drop Data Output (J2)

The balanced drop data output connection is a 15-pin female D connector located at the
front of the breakout panel. Screw locks are provided for mechanical security of the
mating connector.

Signal Function

Name

Pin #

Ground GND

2,

4

Drop Data Output

DDO–A
DDO–B

1
9

Drop Data Output

DDO–A
DDO–B

3
11


For J2 selections, use S1 and S5 located at the rear of the panel.

Signal Function

Name

Switch

Switch #

Position

Balanced Drop Data Output
(DCE/DTE Select)

DDO S5 N/A UP

Unbalanced Drop Data Output

DDO

S1

5, 6/7, 8

OFF/ON

Balanced Drop Data Output

DDO

S1

5, 6/7, 8

ON/OFF

NOTE

S1 is ON in the down position (toward PCB).