beautypg.com

Summary of specifications, Chapter 5. summary of specifications – Comtech EF Data CRS-170 User Manual

Page 31

background image

CRS-170 1:1 Redundancy Switch

Revision 1

Installation and Operations Manual

MN/CRS170.IOM

33

Chapter 5. SUMMARY OF

SPECIFICATIONS

Equipment Type

L-Band 1:1 Redundancy Switch

Manufacturer

Comtech EF Data, Tempe, Arizona

Modems
Supported

Comtech EF Data CDM-600L with CRS-150 1:1 Data Switch
Comtech EF Data SDM-300L3 with SMS-301 1:1 Data Switch

Operating Modes

Fully Automatic under control of supporting 1:1 switch.
Manual under control of supporting 1:1 switch.

Architecture

Full bridging architecture when supported by CRS-150, or SMS-301 data
switching and control, with configuration synchronization.
Tx redundancy supports all BUC interface signals (RF, 10 MHz reference, FSK
communications, and power supply)
Rx IF signal fed to both Online and Standby units. Rx switching supports all LNB
interface signals (RF, 10 MHz reference, and power supply.)

Switch Conditions

Tx/Rx switching follows state of supporting data switching via control input from
data switch.

IF Switching/
Splitting

Tx IF: Switched by RF relay (1 dB max loss, 40 dB min ON/OFF isolation)
Rx IF: Passive power splitting (7 dB max loss)

BUC Power
Switching

Switched by power relay (60VDC max, 4A max)

BUC 10 MHz
Reference
Switching

Switched by relay (1 dB max loss, 70dB min ON/OFF isolation)

BUC FSK Comm
Switching

Switched by relay (70dB min ON/OFF isolation)

LNB Power
Switching

Switched by power relay (28 VDC max, )

LNB 10 MHz
Reference
Switching

Switched by relay (1 dB max loss, 70dB min ON/OFF isolation)

Tx-Rx Isolation

90dB min, 950-1950 MHz

IF Impedance

Optimized for 50Ω (> 10 dB return loss on external IF ports)

IF Connectors

50

Ω Type N Female

IF Frequency
range

950-1950 MHz