Summary of specifications, Chapter 5. summary of specifications – Comtech EF Data CRS-170 User Manual
Page 31
CRS-170 1:1 Redundancy Switch
Revision 1
Installation and Operations Manual
MN/CRS170.IOM
33
Chapter 5. SUMMARY OF
SPECIFICATIONS
Equipment Type
L-Band 1:1 Redundancy Switch
Manufacturer
Comtech EF Data, Tempe, Arizona
Modems
Supported
Comtech EF Data CDM-600L with CRS-150 1:1 Data Switch
Comtech EF Data SDM-300L3 with SMS-301 1:1 Data Switch
Operating Modes
Fully Automatic under control of supporting 1:1 switch.
Manual under control of supporting 1:1 switch.
Architecture
Full bridging architecture when supported by CRS-150, or SMS-301 data
switching and control, with configuration synchronization.
Tx redundancy supports all BUC interface signals (RF, 10 MHz reference, FSK
communications, and power supply)
Rx IF signal fed to both Online and Standby units. Rx switching supports all LNB
interface signals (RF, 10 MHz reference, and power supply.)
Switch Conditions
Tx/Rx switching follows state of supporting data switching via control input from
data switch.
IF Switching/
Splitting
Tx IF: Switched by RF relay (1 dB max loss, 40 dB min ON/OFF isolation)
Rx IF: Passive power splitting (7 dB max loss)
BUC Power
Switching
Switched by power relay (60VDC max, 4A max)
BUC 10 MHz
Reference
Switching
Switched by relay (1 dB max loss, 70dB min ON/OFF isolation)
BUC FSK Comm
Switching
Switched by relay (70dB min ON/OFF isolation)
LNB Power
Switching
Switched by power relay (28 VDC max, )
LNB 10 MHz
Reference
Switching
Switched by relay (1 dB max loss, 70dB min ON/OFF isolation)
Tx-Rx Isolation
90dB min, 950-1950 MHz
IF Impedance
Optimized for 50Ω (> 10 dB return loss on external IF ports)
IF Connectors
50
Ω Type N Female
IF Frequency
range
950-1950 MHz