background image

CRS-170 1:1 Redundancy Switch

Revision 1

Installation and Operations Manual

MN/CRS170.IOM

23

Chapter 3. FUNCTIONAL DESCRIPTION

The CRS-170 L Band 1:1 Switch module performs the transmit and receive coaxial
switching required for redundant modem operation with an outdoor BUC and LNB. It
switches all of the BUC and LNB interface signals that are multiplexed onto the transmit
and receive coaxial cables:

• Tx and Rx L-Band signals

• 10 MHz reference to BUC and LNB

• DC Power to BUC and LNB

• FSK signaling to the BUC

Operation with two CDM-600L modems requires an additional CRS-150 1:1 switch for
terrestrial data switching and 1:1 control, while operation with two SDM-300L3 modems
requires an additional SMS-301 1:1 switch to handle terrestrial data and control. Thus,
there are three functional configurations for the CRS-170.