Figure 5-15 – Comtech EF Data CDS-100 User Manual
Page 74
CDS-100 Diversity Switch
MN-CDS100
Cables and Connections
Revision 1
5–18
5.4.1
CDS-100 CDM-850 Control Interface Cabling Using Kit
KT-0000265
1)
Excluding modems, the KT-0000265 CDS-100 Diversity Switch Kit (Sect. 5.2.1)
provides all components shown in Figure 5-15.
2)
When you connect the Control Interface cables between the CDS-100 and the
CDM-850s, make sure that you securely fasten the screw locks on the Type ‘D’
connectors. This prevents accidental disconnection of the cables, particularly
when you are removing and replacing a backup unit.
3)
The CDM-850 employs 10/100/1000 Ethernet (Gigabit Ethernet, also referred to
throughout this chapter as GigE or GbE) as its sole terrestrial data interface. All
cables and switches must be user-supplied. See Sect. 5.4.2 for the CDM-850
Gigabit Ethernet terrestrial data interface configuration and connection
examples and details.
CAUTION – It is ESSENTIAL that you make the control connections correctly.
CEFD Part No.
Qty
Description
CA/WR9378-4
2
Control Cable – Universal, DB-9M, 4’
Figure 5-15. CDM-850 Unit-to-Switch Control Connections (CEFD Kit KT-0000265)