How to use your unit – DeWalt DeVILBISS User Manual

Page 16

background image

Cooling System (not shown): This
compressor contains an advanced
design cooling system. At the heart
of this cooling system is an
engineered fan. It is perfectly normal
for this fan to blow air through the
vent holes in large amounts. You
know that the cooling system is
working when air is being expelled.
Air Compressor Pump (not shown):
Compresses air into the air tank.
Working air is not available until the
compressor has raised the air tank
pressure above that required at the
air outlet.
Check Valve: When the air
compressor is operating, the check
valve is "open", allowing compressed
air to enter the air tank. When the air
compressor reaches "cut-out"
pressure, the check valve "closes",
allowing air pressure to remain inside
the air tank.

Pressure Release Valve: The
pressure release valve located on the
side of the pressure switch, is
designed to automatically release
compressed air from the compressor
head and the outlet tube when the air
compressor reaches "cut-out"
pressure or is shut off. The pressure
release valve allows the motor to
restart freely. When the motor stops
running, air will be heard escaping
from this valve for a few seconds. No
air should be heard leaking when the
motor is running, or continuous
leaking after unit reaches "cut-out"
pressure.

16- ENG

D23766

Pressure

Release

Valve

Check Valve

Before Starting

Break-in instructions

Serious damage
may result if the

following break-in instructions are
not closely followed.
This procedure is required before the
air compressor is put into service and
when the check valve or a complete
compressor pump has been
replaced.

1.

Make sure the On/Auto/Off lever
is in the "Off" position.

NOTE: If quick connect is installed,
pull coupler back until it clicks to
prevent air from escaping through the
quick connect.

2.

Check oil level in pump. See
"Oil" paragraph in the
"Maintenance" section for
instructions.

3.

Plug the power cord into the
correct branch circuit receptacle.
(Refer to Voltage and Circuit
Protection paragraph in the
Installation section of this
manual.)

4.

Open the drain valve fully
(counter-clockwise) to permit air
to escape and prevent air
pressure build up in the air tank
during the break-in period.

5.

Move the On/Auto/Off lever to
"On/Auto" position. The
compressor will start.

6.

Run the compressor for 20

How to Use Your Unit

How to Stop:

1.

Set the On/Auto/Off lever to
"Off".

Air Intake Filter (not shown) This
filter is designed to clean air coming
into the pump. This filter must always
be clean and ventilation openings
free from obstructions. See
"Maintenance".