DeWalt OIL FREE PORTABLE AIR COMPRESSOR D55146 User Manual
800-4-d
In
s
t
r
u
c
t
Io
n
M
a
n
u
a
l
G
u
Id
e
d
'u
t
Il
Is
a
t
Io
n
M
a
n
u
a
l
d
e
In
s
t
r
u
c
c
Io
n
e
s
d
55
14
6
o
il
Fr
ee
P
o
rt
ab
le
a
ir
c
o
m
p
re
ss
o
r
c
o
m
p
re
ss
eu
r
d
’a
ir
p
o
rt
at
if
sa
ns
h
ui
le
c
o
m
p
re
so
r
d
e
ai
re
s
in
a
ce
ite
p
o
rt
át
il
IN
S
TR
U
C
TI
V
O
D
E
O
P
E
R
A
C
IÓ
N
,
C
E
N
TR
O
S
D
E
S
E
R
V
IC
IO
Y
P
Ó
LI
Z
A
D
E
G
A
R
A
N
TÍ
A
.
a
d
V
e
r
t
e
n
c
Ia
:
LÉ
A
S
E
E
S
TE
IN
S
TR
U
C
TI
V
O
A
N
TE
S
D
E
U
S
A
R
E
L
P
R
O
D
U
C
TO
.
D
e
WALT Industrial Tool Co., 701 East Joppa Road, Baltimore, MD 21286
(AUG10) Part No. N087150 D55146 Copyright © 2007, 2008, 2009, 2010 D
e
WALT
The following are trademarks for one or more D
e
WALT power tools: the yellow and black color scheme; the “D”
shaped air intake grill; the array of pyramids on the handgrip; the kit box configuration; and the array of lozenge-
shaped humps on the surface of the tool.
If you have questions or comments, contact us.
Pour toute question ou tout commentaire, nous contacter
.
Si tiene dudas o comentarios, contáctenos.
1-800-4-D
e
W
AL
T • www
.dewalt.com
Definitions: Safety Guidelines
The definitions below describe the level of severity for each signal word. Please read
the manual and pay attention to these symbols.
DANGER: Indicates an imminently hazardous situation which, if not avoided, will
result in
death or serious injury.
WARNING: Indicates a potentially hazardous situation which, if not avoided, could
result in
death or serious injury.
CAUTION: Indicates a potentially hazardous situation which, if not avoided, may
result in
minor or moderate injury.
NOTICE: Indicates a practice not related to personal injury which, if not avoided,
may result in property damage.
IF YOU HAVE ANY QUESTIONS OR COMMENTS ABOUT THIS OR ANY D
e
WALT TOOL,
CALL US TOLL FREE AT:
1-800-4-d
e
Walt (1-800-433-9258)
Important Safety Instructions
WARNING: Do not operate this unit until you read this instruction manual for safety,
operation and maintenance instructions.
WARNING: This product contains chemicals known to the State of California to cause
cancer, and birth defects or other reproductive harm.
Wash hands after handling.
WARNING: Some dust contains chemicals known to the State of California to cause
cancer, birth defects or other reproductive harm such as asbestos and lead in lead based
paint.
Save theSe InStructIon
DANGER: RISk Of ExPlOSION OR fIRE
What can haPPen
hoW to PreVent It
• It is normal for electrical contacts with-
in the motor and pressure switch to
spark.
• Always operate the compressor in a well
ventilated area free of combustible materi-
als, gasoline, or solvent vapors.
• If electrical sparks from compressor
come into contact with flammable
vapors, they may ignite, causing fire or
explosion.
• If spraying flammable materials, locate com-
pressor at least 20' (6.1 m) away from spray
area. An additional length of hose may be
required.
• Store flammable materials in a secure loca-
tion away from compressor.
• Restricting any of the compressor ven-
tilation openings will cause serious
overheating and could cause fire.
• Never place objects against or on top of
compressor pump.
• Operate compressor in an open area at least
12" (30.5 cm) away from any wall or obstruc-
tion that would restrict the flow of fresh air to
the ventilation openings.
• Operate compressor in a clean, dry well ven-
tilated area. Do not operate unit indoors or in
any confined area.
• Unattended operation of this product
could result in personal injury or prop-
erty damage. To reduce the risk of fire,
do not allow the compressor to operate
unattended.
• Always remain in attendance with the prod-
uct when it is operating.
• Always turn off and unplug unit when not in
use.
DANGER: RISk TO BREATHING (ASPHyxIATION)
What can haPPen
hoW to PreVent It
• The compressed air directly from your
compressor is not safe for breathing.
The air stream may contain carbon mon-
oxide, toxic vapors, or solid particles
from the air tank. Breathing these con-
taminants can cause serious injury or
death.
• Never use air obtained directly from the com-
pressor to supply air for human consumption.
The compressor is not equipped with suitable
filters and in-line safety equipment for human
consumption.
• Exposure to chemicals in dust created
by power sanding, sawing, grinding,
drilling, and other construction activi-
ties may be harmful.
• Sprayed materials such as paint, paint
solvents, paint remover, insecticides,
weed killers, may contain harmful
vapors and poisons.
• Work in an area with good cross ventilation.
Read and follow the safety instructions pro-
vided on the label or safety data sheets for
the materials you are spraying. Always use
certified safety equipment: NIOSH/OSHA
respiratory protection or properly fit ting face
mask designed for use with your specific
application.
WARNING: RISk Of BURSTING
air tank: On February 26, 2002, the U.S. Consumer Product Safety Commission published
Release # 02-108 concerning air compressor tank safety:
Air compressor receiver tanks do not have an infinite life. Tank life is dependent upon several
factors, some of which include operating conditions, ambient conditions, proper installa-
tions, field modifications, and the level of maintenance. The exact effect of these factors on
air receiver life is difficult to predict.
If proper maintenance procedures are not followed, internal corrosion to the inner wall of the
air receiver tank can cause the air tank to unexpectedly rupture allowing pressurized air to
suddenly and forcefully escape, posing risk of injury to consumers.
Your compressor air tank must be removed from service by the end of the year shown on
your tank warning label.
The following conditions could lead to a weakening of the air tank, and result in a violent air
tank explosion:
What can haPPen
hoW to PreVent It
• Failure to properly drain condensed
water from air tank, causing rust and
thinning of the steel air tank.
• Drain air tank daily or after each use. If air tank
develops a leak, replace it immediately with a
new air tank or replace the entire compressor.
• Modifications or attempted repairs to the
air tank.
• Never drill into, weld, or make any modifications
to the air tank or its attachments. Never
attempt to repair a damaged or leaking air
tank. Replace with a new air tank.
• Unauthorized modifications to the safety
valve or any other components which
control air tank pressure.
• The air tank is designed to withstand specific
operating pressures. Never make adjustments
or parts substitutions to alter the factory set
operating pressures.
attachments & accessories:
• Exceeding the pressure rating of air
tools, spray guns, air operated acces-
sories, tires, and other inflatables can
cause them to explode or fly apart, and
could result in serious injury.
• Follow the equipment manufacturers
recommendation and never exceed the
maximum allowable pressure rating of
attachments. Never use compressor to
inflate small low pressure objects such as
children’s toys, footballs, basketballs, etc.
tires:
• Over inflation of tires could result in
serious injury and property damage.
• Use a tire pressure gauge to check the tires
pressure before each use and while inflating
tires; see the tire sidewall for the correct tire
pressure.
note: Air tanks, compressors and similar
equipment used to inflate tires can fill small
tires very rapidly. Adjust pressure regulator on
air supply to no more than the rating of the
tire pressure. Add air in small increments and
frequently use the tire gauge to prevent over
inflation.
WARNING: RISk Of ElECTRICAl SHOCk
What can haPPen
hoW to PreVent It
• Your air compressor is powered by
electricity. Like any other electrically
powered device, If it is not used properly
it may cause electric shock.
• Never operate the compressor outdoors when
it is raining or in wet conditions.
• Never operate compressor with protective
covers removed or damaged.
• Repairs attempted by unqualified
personnel can result in serious injury or
death by electrocution.
• Any electrical wiring or repairs required on this
product should be performed by a D
e
WALT
factory service center or a D
e
WALT authorized
service center in accordance with national
and local electrical codes.
•
electrical Grounding: Failure to provide
adequate grounding to this product
could result in serious injury or death
from electrocution. See
Grounding
Instructions under Installation.
• Make certain that the electrical circuit to
which the compressor is connected provides
proper electrical grounding, correct voltage
and adequate fuse protection.
WARNING: RISk fROm flyING OBjECTS
What can haPPen
hoW to PreVent It
• The compressed air stream can cause
soft tissue damage to exposed skin
and can propel dirt, chips, loose par-
ticles, and small objects at high speed,
resulting in property damage or personal
injury.
• Always wear certified safety equipment: ANSI
Z87.1 eye protection (CAN/CSA Z94.3) with
side shields when using the compressor.
• Never point any nozzle or sprayer toward any
part of the body or at other people or animals.
• Always turn the compressor off and bleed
pressure from the air hose and air tank before
attempting maintenance, attaching tools or
accessories.
WARNING: RISk Of HOT SURfACES
What can haPPen
hoW to PreVent It
• Touching exposed metal such as the
compressor head, engine head, engine
exhaust or outlet tubes, can result in
serious burns.
• Never touch any exposed metal parts on
compressor during or immediately after
operation. Compressor will remain hot for
several minutes after operation.
• Do not reach around protective shrouds or
attempt maintenance until unit has been
allowed to cool.
WARNING: RISk fROm mOvING PARTS
What can haPPen
hoW to PreVent It
• Moving parts such as the pulley, fly-
wheel, and belt can cause serious injury
if they come into contact with you or
your clothing.
• Never operate the compressor with guards or
covers which are damaged or removed.
• Keep your hair, clothing, and gloves away
from moving parts. Loose clothes, jewelry, or
long hair can be caught in moving parts.
• Air vents may cover moving parts and should
be avoided as well.
• Attempting to operate compressor with
damaged or missing parts or attempt-
ing to repair compressor with protective
shrouds removed can expose you to
moving parts and can result in serious
injury.
• Any repairs required on this product should
be performed by a D
e
WALT factory service
center or a D
e
WALT authorized service center.
WARNING: RISk Of UNSAfE OPERATION
What can haPPen
hoW to PreVent It
• Unsafe op er a tion of your air compres-
sor could lead to se ri ous in ju ry or death
to you or others.
• Review and understand all instructions and
warnings in this manual.
• Be come fa mil iar with the op eration and con
trols of the air compressor.
• Keep operating area clear of all persons,
pets, and obstacles.
• Keep chil dren away from the air compressor
at all times.
• Do not operate the product when fatigued or
under the influence of alcohol or drugs. Stay
alert at all times.
• Never defeat the safety fea tures of this prod
uct.
• Equip area of operation with a fire extin-
guisher.
• Do not op er ate machine with missing, bro-
ken, or un au tho rized parts.
• Never stand on the compressor.
WARNING: RISk Of fAllING
What can haPPen
hoW to PreVent It
• A portable compressor can fall from
a table, workbench, or roof causing
damage to the compressor and could
result in serious injury or death to the
operator.
• Always operate compressor in a stable
secure position to prevent accidental move-
ment of the unit. Never operate compressor
on a roof or other elevated position. Use
additional air hose to reach high locations.
WARNING: RISk Of INjURy fROm lIfTING
What can haPPen
hoW to PreVent It
• Serious injury can result from attempting
to lift too heavy an object.
• The compressor is too heavy to be lifted by
one person. Obtain assistance from others
before lifting.
WARNING: RISk fROm NOISE
What can haPPen
hoW to PreVent It
• Under some conditions and duration of
use, noise from this product may con-
tribute to hearing loss.
• Always wear proper hearing protection during
use.
Save theSe InStructIonS
For Future uSe
components (Fig. 1)
A. Sliding Handles
H. Pressure Switch
B. Handle Grip
I. Cord Wrap
C. Storage Support
J. Air Filter
D. Regulated Pressure Gauge
K. Tank Pressure Gauge
E. Quick Connects
L. Auto(I)/Off(O) Switch
F. Regulator
M. Drain Valve
G. Safety Valve
FeatureS (FIG. 1)
auto/oFF sWItch
Place this switch (L) in the AUTO (I) position to provide automatic power to the pressure
switch and OFF (O) to remove power at the end of each use.
Pressure sWItch
The pressure switch (H) automatically starts the motor when the air tank pressure drops
below the factory set
cut-in pressure. It stops the motor when the air tank pressure
reaches the factory set
cut-out pressure.
saFety ValVe
If the pressure switch does not shut off the air compressor at its cut-out pressure setting,
the safety valve (G) will protect against high pressure by popping out at its factory set
pressure (slightly higher than the pressure switch cut-out setting).
check ValVe
When the air compressor is operating, the check valve is open, allowing compressed air
to enter the air tank. When the air compressor reaches cut-out pressure, the check valve
closes, allowing air pressure to remain inside the air tank.
tank Pressure GauGe
The tank pressure gauge (K) indicates the reserve air pressure in the tank.
reGulated Pressure GauGe
The regulated pressure gauge (D) indicates the air pressure available at the outlet side of
the regulator. This pressure is controlled by the regulator.
reGulator
The regulator (F) controls the air pressure shown on the regulated pressure gauge. Pull the
knob out and turn clockwise to increase pressure and counterclockwise to decrease pressure.
When the desired pressure is reached push knob in to lock in place. The regulated pressure
range is 7–150 psi.
WARNING: Risk of Bursting. Too much air pressure causes a hazardous risk of bursting.
Check the manufacturer’s maximum pressure rating for air tools and accessories. The
regulator outlet pressure must never exceed the maximum pressure rating.
unIVersal QuIck connect BodIes
The universal quick connect body (E) accepts the three most popular styles of quick connect
plugs: Industrial, automotive, and ARO. One hand push-to-connect operation makes
connections simple and easy. The two quick connect bodies allow the use of two tools at
the same time.
draIn ValVe
The drain valve (M) is located at the base of the air tank and is used to drain condensation
at the end of each use. See draining air tank under Maintenance.
coolInG systeM
This compressor contains an advanced design cooling system. It is normal for this fan to
blow air through the vent holes in large amounts. The cooling system is working when air
is expelled.
aIr coMPressor PuMP
The pump compresses air into the air tank. Working air is not available until the compressor
has raised the air tank pressure above that required at the air outlet.