INSTALLATION

Initial Light Conditions

In order to prevent a incorrect operation of the

keyboard, when the hob is connected, if the direct

environmental lighting conditions are excessive

(i.e. halogen hood lights on), the user interface

operation is stopped until the correct light

conditions are recovered.

The displays of the User Interface heaters are

switched on and the control operation stopped

5 mm

50 min.

Min. 4

20-40

Max. 50

ATTENTION:

To guarantee a correct functioning of the appliance it is important to

provide the work surface, during the installation, of a 4mm space for

the length of the recess on the front side of the furniture.

This, because the electrical controls have a guard which,

if the

electronic system exceeds a 85°C temperature, switches off

the hob until the temperature returns below this limit. So during

the functioning, to guarantee a rush of air which maintains the right

temperature, a fan starts up.

Provide the assembling with an underlying cover which ensures

the rush of air from the back of the furniture or, if the hob is

installed over an oven, a suitable insulation to guarantee that the

temperature does not exceed 85°C.

Please provide a protection below to ensure the correct air flow

from the back of the cabinet, or, if the hob is installed above

the oven, please ensure adequate insulation to be sure of not

exceeding temperature.

If this happens it can cause damages to the electronic system, for

which the manufacturer does not have responsibilities.

Air inlet

Air outlet

Electrical connection.

•The appliance must be installed by a qualified

technician, who knows security and installation

rules in force. In particular, local power institution

rules must be observed.

•Check that the voltage indicated on the appliance

indicator plate corresponds to the voltage used in

your house. The indicator plate is placed in the

back side of the hob.

•The grounding is compulsory according to the law.

All the electric wires and grounding conductors

should have appropriate dimensions.

The manufacturer declines all responsibility

for damages on person or things caused by

the non-observance of rules written above.

The electrical connection between the hob

and a possible built-in oven must be installed

separately, whether for electrical safety

reasons, or to simplify the extraction of the

appliances.

In the case of a direct connection to the net, it

is neccesary to interpose a mono-pole switch

between the appliance and the net , with a minimal

3mm opening between the contacts.

The installer is responsible for the correct

electrical connection and of the compliance of

the safety rules.

Before beginning the connection ,make sure that:

•the cable has the grounding and is make

according to law;

•the cable could bear the highest load of the

machine, shown in the indicator placed on the

appliance;

•the charging voltage is included in the

characteristics indicator;

•the cable is plug-compatible with the appliance.

On the contrary replace the cable; do not use

extansions or multiplexes;

•the grounding wire (yellow/green coloured)

is connected to the terminal board on the point

indicated with the respective sign, and is longer

than other conductor wires;

•the cable must not undergo foldings or

compressions;

•the cable must be periodically controlled and

changed only by authorised technicians.

the manufacturer declines all responsabilities