beautypg.com

Problems and solutions – Caple C993i User Manual

Page 13

background image

13

PROBLEMS AND SOLUTIONS

Below are listed some possible fault messages

for which it is necessary to seek technical

support.

Cooking zone temperature sensor:

Short-circuit: in the corresponding cooking

zone, the symbols “F” and “1” are alternatively

visualized.

Open circuit: in the corresponding cooking

zone, the symbols “F” and “2” are alternatively

visualized.

No operation: The corresponding heater display

alternates between an ‘F’ and a "7"

Power temperature sensor:

Short-circuit: if the 2 elements controlled by the

induction generator are in short-circuit, “F” and “3”

are visualized alternatively.

Open circuit: if the 2 elements controlled by the

induction generator have an open circuit, “F” and

“4” are visualized alternatively.

Loss of zero crossing detection: the display

of the 2 heaters controlled by the induction

generator with which communication has been

lost alternates between 'F' and '8’.

Comunications loss:

•If the 2 elements controlled by the induction

generator lost comunications, “F” and “5” are

visualized alternatively.

Generator overcurrent:

•if the 2 elements controlled by the induction

generator are overloaded, “F” and “9” are

visualized alternatively.

Generator overheating:

•if the 2 elements controlled by the induction

generator are overheated, “POWER LEVEL” and

“C” are visualized alternatively.

Afterheat:

For safety reasons these information are the most

important.

If the hob is switch off, the zones which show

the power are fixed on “H”.

if the hob is switch on, the zones which show

the power visualize alternatively “H” and “0”.

If the power level is not “0”, in the display is shown

the selected level.

Cooking zone without or with an inadequate

pot:

•if the selected level is “0”, this one is also shown in

the indicator.

•If it is different from “0”, it is also shown in the

indicator, but it flashes.

Authomatic actions in case of failure:

If there are failures on the temperature sensor

and on the cooking zones power sensor, these

immediately are switch off and the keys (+/-) are

blocked.

This happens also if there are loss of

comunication with the induction generator or

overloading.

If a cooking zone without a pot is selected for

more than 30 seconds, passed this time the

zone will automatically switch off.