BUG-O Systems BVW-1000 User Manual
Page 13
12
3
. Lighting and smoke exhaustion:
In front of and behind the operation position inside of the machine framework, there are AC
220V/50Hz explosion-proof lamps,
as shown in Fig. 5
and they are used to assembl
e the welding
groove, the welding torch and the slider.
Fig.5. Lighting
Both the vertical
Mig welding and self-shielded welding with flux-cored wires,
produce a large amount of welding fumes. To improve the operation environment
and reduce the harm the welding fume to operators inside of the machine framework, a
ventilation fan and a smoke exhaustion system are installed
above the welding machine
framework, as shown in Fig. 6.
Fig.6. Smoke exhaustion system
4. Gas cylinder rack
The gas cylinder rack with an “L” shape, which has a height 1.1m, can be used to lay 2~3
gas cylinders for the CO
2
gas. Furthermore, this gas cylinder can move along with the
welding machine framework. The standard gas cylinder is located in front of the
smoke exhaustion
system
explosion-proof lamp
explosion-proof lamp