BCI 272E User’s Manual

Digital Fiber Optic Video/Audio/Data Transport System

Broadata Technical Support, [email protected]

13

RS-422 differential serial data
The 272E transmits differential data signals compatible with Full
Duplex RS-422 electrical signals. Note that RS-422 option is
factory set. The RS-422 does not support handshaking
control signals.
Use the following steps for data transmission.

1.

For the near-end, label and connect one serial computer
data cable to the user’s RS-422 device.

2.

Connect the other end of this cable to the front panel RS-422
terminal block connector on the 272E.

3.

At the far-end, label and connect one serial computer data
cable to the remote RS-422 device.

4.

Connect the other end of this cable to the front panel RS-422
terminal block connector on the far-end 272E unit.

Figure 2-6

RS-422 Terminal block pinout

Figure 2-7 shows pin connections between the 272E unit (as a
DCE unit) and the user’s RS-422 device (as a DTE unit).

IN

OUT

RS-422

_

+

_

+