beautypg.com

Problems and solutions – Bompani BO364AA/E User Manual

Page 10

background image

10

3PCLIOBILBO-02

PROBLEMS AND SOLUTIONS

Displaying Special Statuses

The corresponding heater display alternates between two characters depending on the status.

Event

Heater

status

Start

conditions

End

conditions

Action

Heater

Display

fore

(1 sec.)

Heater

Display

back

(1 sec.)

Priority

Power increment

not allowed (only

for ECO models)

On/Off

Asked Cooktop

power >

Cooktop ECO

power limit

2 sec

--------

'r'

'r'

1

Heater without

pan

On

No pan or not

suitable pan

over the heater

Heater Off

In 1 minute Heater

off

'Power'

'u'

2

Heater over

temperature

Off

Heater

Temperature >

90ºC

Heater

Temperature <

80ºC

---------

' ' o 'H'

'C'

3

Heater over

temperature

On

No power is

delivered to the

heater

'Power'

Induction

generator over

temperature

Off

Heat sink

Temperature >

90ºC

Heat sink

Temperature <

80ºC

---------

' ' o 'H'

'c'

4

Induction

generator over

temperature

On

No power is

delivered to the

heater

'Power'

Heater with

residual heat

Off

Heater

Temperature >

50ºC

Heater

Temperature <

40ºC

---------

'H'

'H'

5

PROBLEMS AND SOLUTIONS

Errors/Alarms

The corresponding heater display alternates between two characters depending on the Error.

F

7

Appliance errors

Event

(Visualization Priority

Order)

Description

Action

End

All Heater Displays

(fore 0.5 sec.

back 0.5 sec)

FalloSw

Software Error

App Off (*)

--------

F0

FalloKeyOnOffEmitter

Safety Key Error

App Off (*)

--------

FA

FalloKeyOnOffReceiver

Safety Key Error

App Off (*)

--------

FC

FalloNtcShort

Touch NTc Error

App Off (*)

--------

FE

FalloNtcOpen

Touch NTc Error

App Off (*)

---------

Ft

FalloOverTemp

Touch NTc Error

App Off (*)

T < 90°C

Fc

FalloEepromChecksum

Eeprom Checksum

Error

App Off (*)

--------

FH

FalloAdc

Security Key Error

App Off (*)

--------

FJ

FalloAmbientLight

Keyboard Error

App Off (*)

Light

Condition

FL

FalloDivisor

Security Key Error

App Off (*)

--------

FU

(*) All heaters switched Off and locked