1 insider will not run, 2 insider will not stay running – Belshaw Adamatic INSIDER Ventless Donut System User Manual
Page 42

Belshaw Bros., Inc.
• www.belshaw.com • Phone 206-322-5474 • Fax 206-322-5425
16 MN-1853EN
Insider
TS
1 INSIDER WILL NOT RUN
Possible Cause
What To Do
The power cord is not plugged in, or the
outlet has no power.
Connect the machine to a good power
source.
The power cord is defective
Replace the power cord.
The circuit breaker has been tripped
Reset it by lifting cover on electrical
enclosure and turn Insider breaker to
“OFF” and then to “ON”.
There is a loose connection
See if circuit breaker has been tripped.
Test circuits and repair it.
WARNING
To avoid electrical shock injuries, before
doing any of the following, unplug the
machine.
2 INSIDER WILL NOT STAY RUNNING
Possible Cause
What To Do
Fuse has blown out
Check fuses located inside electrical
enclosure and replace. If condition
continues look for electrical short.
Fire suppression system has fired
Call the Pyro-Chem certified personnel
to reset & change the system. The
interlock switch in the control head will
prevent the Insider from running.
Hood doors are not closed or making
contact with interlock switches
Close the doors and latch tight or adjust
interlock switch position.
Grease baffle filter not installed or
properly seated on interlock switch.
Install filter or adjust interlock switch at
the bottom of filter opening.
Pre-filter not installed or locked in place Install filter and lock into place with slide
bolts.
Electronic Air Cleaner (air cleaner cell)
not installed or locked in place.
Install cell and lock into place with slide
bolt. Push the cell all the way back
against rear stop and engage slide bolt
into hole in sheet metal baffle.