beautypg.com

1 operation, Startup/run, Shutdown – Belshaw Adamatic INSIDER Ventless Donut System User Manual

Page 15

background image

Belshaw Bros., Inc.

• www.belshaw.com • Phone 206-322-5474 • Fax 206-322-5425

Insider OM

MN-1852EN

1

1 Operation

Startup/Run

1. Make sure all filters are properly installed

and all doors are closed.

2. Check the fire suppression cylinder gauge

for the proper range of pressure and the red
control box indicator for the set mode.

CAUTION

Do not operate the Insider if gauge

pressure is low or set mode is not

displayed. The fire suppression system

will not operate.

3. Plug the Mark II, V, or IX Fryer power cord

into the receptacle labeled “Fryer” on the
electrical box. The large hole in the counter
top is for the power cord of the fryer.

CAUTION

Do not operate the Insider with

polycarbonate windows or doors

removed or open. Fire suppression

system will cause hot shortening to

splatter causing serious injury and

burns.

4. Turn on the fryer, Insider and auxiliary

circuit breakers.

5. Plug the Insider main power plug into the

customer supplied power receptacle.

6. Push the green "Start" button to energize the

unit. Hold the “Start” button in for a few
seconds while the proper airflow is attained.

7. The system must be on to provide power to

the air filtration system, overhead lights,
auxiliary outlet, fryer and cutter. (See Mark

II, V, or IX Fryer manual for information on
fryer and cutter operation).

8. After charging and setup by certified

personnel, the fire suppression system is
always operational.

9. Note: If manual operation of the fire

suppression system is required, the system
can be actuated by pulling the handle
straight out. The manual actuator is located
to the right of the red fire suppression
cylinder.

Shutdown

1. Pushing the "Stop" button shuts off all

power to the unit, including fryer.

2. Opening the hood doors, removing a filter or

operation of the fire suppression system will
shutdown the Insider.

3. The unit will not restart if the fire

suppression system has been operated.
Recharging and setup by certified personnel
will be required.

4. After shutdown disconnect power and let

shortening cool to 100

° F/38° C before

disassembling or cleaning fryer. Refer to
Mark II, V, or IX manual for instructions.

WARNING

Electrical Shock Hazard. Have power off

and disconnected at source before doing

any cleaning or maintenance.