11. Slide the aluminum mesh pre-filter all the

way into the groove on the left side of the
cell, then push the cell all the way back
against the angle stop and lock into place
with the slidebolt. The slidebolt will hold
the pre-filter in place and hold the cell and
pre-filter against the inside interlock
switches. Make sure the slidebolt is engaged
through the small locating hole in the left
side compartment.

12. Slide the air-circulating baffle all the way

into the cell’s right side groove.

13. Install the damper sleeve assembly by

dropping it into the large hole on the top of
the hood. Install with the fuse link pivot
assembly towards the hinge side.

CAUTION

Installing damper the wrong way will

damage the interlock switch.

14. Place two carbon filters into the filter slide

tray and install through the end door on top
of the support guides. The tray must be
centered in the door opening, before opening
the door.

CAUTION

Failure to center the tray may result in

damage to tray and door.

15. Make sure the top carbon filter is in place

and pushing against the inside interlock
switch. There is a 1” diameter disc that
pushes against the top filter. The disc and
switch are adjustable if required to make the
interlock function. Shutting the door pushes
the top filter against the interlock switch.


WARNING

The Insider will not run with only one

carbon filter. All the filters and door

interlocks must be made before the

Insider will start.

16. The system is now ready for the certified

fire suppression service personnel to finish
the installation procedure, including arming
the fire damper.

Fire Suppression System

WARNING

THE CHARGING & SETUP OF THE PYRO-

CHEM PLC-240/300 FIRE SUPPRESSION

SYSTEM MUST BE DONE BY CERTIFIED

PERSONNEL ON A REGULAR BASIS

AND THE USE AND MAINTAINENCE OF

THE INSIDER IS TO BE IN ACCORDANCE

WITH NFPA-96.

Note: The fusible links used in the INSIDER are
212º F fusible links.
THE FIRE SUPPRESSION SYSTEM IS
SHIPPED INACTIVE.
The system must be
armed before using. Removing the red control
head internal safety pin and installing the CO2
cartridge is required to arm the fire suppression
system.

WARNING

A customer provided hand portable fire

extinguisher is required on the premises

per NFPA 96 7-10.

Fire Damper System

FD-1300 Dynamic rated multi-blade fire damper

UL-555 1-1/2hr, File No. R11172.

The unit must be armed before using the insider.
Note: the fusible link used in the damper is
212ºF.