11. Slide the aluminum mesh pre-filter all the
way into the groove on the left side of the
cell, then push the cell all the way back
against the angle stop and lock into place
with the slidebolt. The slidebolt will hold
the pre-filter in place and hold the cell and
pre-filter against the inside interlock
switches. Make sure the slidebolt is engaged
through the small locating hole in the left
side compartment.
12. Slide the air-circulating baffle all the way
into the cell’s right side groove.
13. Install the damper sleeve assembly by
dropping it into the large hole on the top of
the hood. Install with the fuse link pivot
assembly towards the hinge side.
CAUTION
Installing damper the wrong way will
damage the interlock switch.
14. Place two carbon filters into the filter slide
tray and install through the end door on top
of the support guides. The tray must be
centered in the door opening, before opening
the door.
CAUTION
Failure to center the tray may result in
damage to tray and door.
15. Make sure the top carbon filter is in place
and pushing against the inside interlock
switch. There is a 1” diameter disc that
pushes against the top filter. The disc and
switch are adjustable if required to make the
interlock function. Shutting the door pushes
the top filter against the interlock switch.
WARNING
The Insider will not run with only one
carbon filter. All the filters and door
interlocks must be made before the
Insider will start.
16. The system is now ready for the certified
fire suppression service personnel to finish
the installation procedure, including arming
the fire damper.
Fire Suppression System
WARNING
THE CHARGING & SETUP OF THE PYRO-
CHEM PLC-240/300 FIRE SUPPRESSION
SYSTEM MUST BE DONE BY CERTIFIED
PERSONNEL ON A REGULAR BASIS
AND THE USE AND MAINTAINENCE OF
THE INSIDER IS TO BE IN ACCORDANCE
WITH NFPA-96.
Note: The fusible links used in the INSIDER are
212º F fusible links.
THE FIRE SUPPRESSION SYSTEM IS
SHIPPED INACTIVE. The system must be
armed before using. Removing the red control
head internal safety pin and installing the CO2
cartridge is required to arm the fire suppression
system.
WARNING
A customer provided hand portable fire
extinguisher is required on the premises
per NFPA 96 7-10.
Fire Damper System
FD-1300 Dynamic rated multi-blade fire damper
UL-555 1-1/2hr, File No. R11172.
The unit must be armed before using the insider.
Note: the fusible link used in the damper is
212ºF.