Installation Instructions


Power Supply Connection

The 5-pin CAGE CLAMP plug connector and mounting flange illustrated is
located on the PC housing in order to connect the power supply.

Socket at the PC housing

Connection socket when
fitted with 100-240 V

AC

,

50-60 Hz power supply
unit (standard)

Technical data

Connecting socket

Number of contacts

5

Contact spacing

5 mm

Minimum conductor cross-section

1.5

mm²

Minimum conductor cross-section

(AWG)

16

Rated voltage (EN)

250 V

Rated voltage (CSA)

300 V

Current EN [A]

12 A

Current CSA [A]

15 A

Length of stripped conductor

8 to 9 mm


Power Supply Configuration

Supplied mains power unit The Industrial PCs is either fitted with a 100-240 V

AC

, 50-60 Hz power

supply unit (standard) or with a 24 V

DC

power supply unit (with the option of

an uninterruptible power supply, UPS).


Current carrying capacity of
the 100-240 V power
supply unit

Output voltages from

the 100-240 V power

supply unit

Current loading
maximum

+3,3 V

16 A

+5 V stand by

2 A

+5 V

25 A

-5 V

0.3 A

+12 V

13 A

-12 V

0.8 A


Current carrying capacity of
the 24 V power supply unit

Output voltages from

the 24 V power supply

unit

Current loading
maximum

+5 V

25 A

-5 V

1 A

+12 V

10 A

-12 V

1.5 A