Fireplace installation, Site selection and preparation – Dimplex DF3033ST User Manual
Page 7

7
Site Selection and Preparation
This section provides instructions
for selecting a location and
preparing the site to install the
fireplace into your Dimplex mantel
surround.
①
Select a suitable location that
is not susceptible to moisture and
is away from drapes, furniture and
high traffic.
②
For ease of electrical hook
up you may wish to locate the
Fireplace Installation
fireplace near an existing outlet
(refer to noTE 1).
③
Store the fireplace in a safe
dry and dust free location.
!
NOTE: The dimensions of
the fireplace are 31 ½ inches
(800 mm) wide x 22 ⅜ inches
(568 mm) high x 9 ⅛ inches
(232 mm) deep. The fireplace
does not require any additional
venting.
①
Install the fireplace assembly
into the mantel (refer to mantel
assembly instructions).
!
NOTE 1: a 15 amp, 120 Volt
circuit is required. a dedicated
circuit is preferred but not
essential in all cases. a
dedicated circuit will be
required if, after installation,
the circuit breaker trips or fuse
blows on a regular basis when
the heater is operating.
additional appliances on the
same circuit may exceed the
current rating of the circuit
breaker.
!
IMPORTANT: If not using a
Dimplex mantel, the fireplace
must be installed in an
enclosure with the following
minimum internal/opening
dimensions (Figure 1).