Scanning Functions 4-29
Field Description
EnableUPCA
Enables/disables the ability to scan UPCA bar
codes. Default: true
EnableUPCE
Enables/disables the ability to scan UPCE0 bar
codes. Default: true
EnableUPCE1
Enables/disables the ability to scan UPCE1 bar
codes. Default: false
EnableEAN8
Enables/disables the ability to scan EAN8 bar
codes. Default: true
EnableEAN13
Enables/disables the ability to scan EAN13 bar
codes. Default: true
EnableEANBklnd
Enables/disables the ability to scan Bookland EAN
bar codes. Default: false
Supplemental
Specifies how to treat UPC and EAN bar codes with
supplemental characters (UPCA+2, for example).
Values are:
USM_REQUIRED
The scanner scans bar codes
with supplemental characters only. For example, it
scans a UPCA+2 bar code, but not UPCA.
USM_IGNORE
The scanner ignores
supplemental characters. For example, it scans a
UPCA+2 bar code as a UPCA.
USM_AUTO
Uses scanning information as
specified in SupRedundancy.
Default: USM_IGNORE
SupRedundancy
If using USM_AUTO for Supplement, this sets the
number of times a symbol without supplemental
information is decoded. Values are 2-20.
Default: 7
XmitUPCACD
Enables/disables the requirement to transmit UPCA
bar codes with the check digit. Default: true
XmitUPCECD
Enables/disables the requirement to transmit UPCE0
bar codes with the check digit. Default: true
XmitUPCE1CD
Enables/disables the requirement to transmit UPCE1
bar codes with the check digit. Default: true