4-18 Programmer’s Manual
Code93
Description
Sets the scanner configuration values for CODE93 bar code.
Syntax
Enable;
FixedLength;
Length1;
Length2;
Instantiate Class
classid=clsid:
C63FC12E-7F89-42BF-9BDA-B2E797632D0F>
Field Description
Enable
Enables/disables the ability to scan Code 93 bar codes.
Default: false
FixedLength
If FixedLength is true, lengths 1 and 2 are fixed; if
FixedLength is false, length 1 is the minimum and
length 2 is the maximum. Default: false
Length1
Length2
Specifies lengths (including start and stop characters)
for Code 93 bar codes.
Length 1: 0, 2-99, Default: 4
Length 2: 0, 2-99, Default: 55
Return Values